background image

20013749

GB

TECHNICAL DATA 

BURNER DESCRIPTION

One stage light oil burner.   

BURNER EQUIPMENT

Flexible pipes with nipples . . . . . . . . . No. 2

Cover  . . . . . . . . . . . . . . . . . . . . . . . .  No. 1

Screws and nuts for flange. . . . . . . . . No. 4

Insulating gasket . . . . . . . . . . . . . . . .  No. 3

Screw with two nuts for flange . . . . . . No. 1

TYPE

448T1

Thermal power – output

19 – 35 kW

1.6 – 3 kg/h

Fuel

Light oil, viscosity  4 –

 

6 mm

2

/s at  20 °C  (1.5 °E)

Electrical supply

Single phase,

230 V 

±

 10% 

~

  50Hz

Motor

Run current  0.7 A – 2850 rpm – 298 rad/s

Capacitor

µ

F

Ignition transformer

Secondary 8 kV – 16 mA

Pump

Pressure  7 – 15 bar

Absorbed electrical power

0.115 kW

– Lock-out lamp and reset button

– Motor

– Capacitor

– Air damper assembly

– Hydraulic jack

– Combustion head

  7 – Combustion head adjustment screw

  8 – Vacuum gauge connection

  9 – Return line

10 – Suction line

11 – Oil pump

Fig. 1

8

D4672

9

10

2

7

1

3

4

5

6

11

Summary of Contents for G3MC

Page 1: ...20013749 2 10 2009 Installation use and maintenance instructions Light oil burner CODE MODEL TYPE 20013629 G3MC 448T1 GB CN One stage operation...

Page 2: ...safety start up use and maintenance of the burner DELIVERY OF THE SYSTEM AND THE INSTRUCTION MAN UAL When the system is delivered it is important that The instruction manual is supplied to the user b...

Page 3: ...t oil viscosity 4 6 mm2 s at 20 C 1 5 E Electrical supply Single phase 230V 10 50Hz Motor Run current 0 7A 2850 rpm 298 rad s Capacitor 4 F Ignition transformer Secondary 8 kV 16 mA Pump Pressure 7 15...

Page 4: ...urner 125 110 194 130 26 4 5 89 213 11 162 D4673 180 75 72 150 4 5 125 It is necessary that the insulating gasket is placed between the boiler door and the burner flange This insulating gasket has six...

Page 5: ...leakage of the valve PRIMING THE PUMP Start the burner and wait for the prim ing Should lock out occur prior to the arrival of the fuel await at least 20 sec onds before repeating the operation A filt...

Page 6: ...burner Unscrew the fissing screws on the burner cover and remove it Unscrew the fissing screws 2 on the plate and remove the control box 1 Screw the two fissing screws 2 and reassemble the burner cov...

Page 7: ...e detachment during ignitions at low tem peratures PUMP PRESSURE 12 bar the pump leaves the factory set at this value 14 bar improves flame retention it is therefore suitable for ignitions at low temp...

Page 8: ...nting the number of turns AIR DAMPER ADJUSTMENT see fig 7 The mobile air damper A operated by the jack B as sures the complete opening of the air intake The regulation of the air rate is made by adjus...

Page 9: ...to 14 bar 4 COMBUSTION HEAD SETTING Regulate the combustion head one set point further ahead than indicated in the instructions Example the instructions require to set the combustion head on set point...

Page 10: ...ion areas and in the combustion product waste pipe Clean the filter in the oil suction line and in the pump Check for correct fuel consumption Check that the burner electrical connections are correct...

Page 11: ...20013749 CN Technical Assistance Centre Assistance Centre Maintenance Contract...

Page 12: ...1 20013749 CN 2 1 4 3 1 448T1 19 35 kW 1 6 3 kg h 20 C 4 6 mm2 s 1 5 E 230V 10 50Hz 0 7A 2850 rpm 298 rad s 4 F 8 kV 16 mA 7 15 bar 0 115 kW 1 2 3 4 5 6 7 8 9 10 11 1 8 D4672 9 10 2 7 1 3 4 5 6 11...

Page 13: ...20013749 2 CN 0 8 0 0 2 0 4 m m m m b b b b a a a a r r r r 1 5 2 2 5 3 kg h 20 25 30 35 kW D5223 0 6 125 110 194 130 26 4 5 89 213 11 162 D4673 180 75 72 150 4 5 125 6 6 2 D5242 D5218 2 S7387...

Page 14: ...r 30 cm Hg 20 H L I D 8 mm I D 10 mm 0 5 1 1 5 2 10 20 40 60 20 40 80 100 A 3 A H L I D 8 mm I D 10 mm 0 0 5 1 1 5 2 3 3 5 35 30 25 20 15 8 6 100 100 100 90 70 30 20 H 4 m H H 4 m 0 1 m D5219 D5220 D5...

Page 15: ...20013749 4 CN 1mm2 4 1 2 1 2 1 Fig 4 2 1 D4677 A 530SE C E F FR P E H I M PE TL TS XP Y...

Page 16: ...R NS Delavan W A E Steinen H Q Danfoss H B 60 80 12 bar 14 bar GPH bar kg h 4 0 40 80 12 1 6 0 2 4 0 50 60 80 12 2 0 1 3 1 0 60 60 80 12 2 4 2 3 6 0 65 60 80 12 2 6 3 3 8 0 75 60 12 3 0 4 4 0 0 65 60...

Page 17: ...20013749 6 CN 6 6mm 2 6 1 6 6 6 6 CO2 CO2 3 1 3 6 6 6 6 7 A B C D D A 0 1 2 3 6 D5323 6 D C D5786 D A B 7 4 A 2 2 5 mm 4 0 3 mm D5230 A 8...

Page 18: ...7 20013749 CN 8 C 1 8 2 Delavan A E Steinen H Danfoss H 3 12 bar 8 C 14 bar 4 2 3 5 Bacharach 1 12 D5229 12 5...

Page 19: ...20013749 8 CN CO2 CO ppm NOx ppm...

Page 20: ...I 37045 Legnago VR Tel 39 0442 630111 http www riello it http www rielloburners com Manufacturing site Riello Heating Equipment Shanghai CO LTD No 388 Jinbai Road Jinshan Industrial Zone 201506 Shang...

Reviews: