燃烧器启动周期

怎样避免燃烧器的损坏和燃烧效果变坏

– 

 燃烧器停机时,烟道必须畅通保证炉膛自然通风。如果烟道关闭了,燃烧器必须从炉膛里面退出来,

退出来之前必须断电。

– 

燃烧器安装和工作的场所,必须有足够的通风面积来保证燃烧所需的通风量。

 

为了检验这一点,在门

窗全部关闭的情况下检验烟气等级确保烟气合格。

– 

如果在燃烧器工作的场所,有引风机的话,检查进风口的面积是否满足通风量的需要。不管如何检

查,燃烧器停机时不要开引风机将炉膛中的烟气抽走造成热量损失。

正常启动

因点火失败而锁定

启动温控开关

加热器

风机电机

点火变压器

电磁阀

火焰

~

120

D5329

~

120

~

12

锁定指示灯

~

12

~

5

Summary of Contents for G5R MC

Page 1: ...20013743 3 04 2011 Installation use and maintenance instructions Light oil burner CODE MODEL TYPE 20013623 G5R MC 447T1 GB CN One stage operation...

Page 2: ...safety start up use and maintenance of the burner DELIVERY OF THE SYSTEM AND THE INSTRUCTION MAN UAL When the system is delivered it is important that The instruction manual is supplied to the user b...

Page 3: ...0 185 kW It is strongly recommended a periodic check of the pump pressure operation annually or better every six months if the burner operation is continuous If the value is lower than 1 bar compared...

Page 4: ...e No 1 Screw with two nuts for flange No 1 Insulating gasket No 3 FIRING RATE OVERALL DIMENSIONS 0 8 0 0 4 Pressure in the combustion chamber mbar 2 3 4 5 Light oil output kg h 25 30 60 Thermal power...

Page 5: ...between the boiler door and the burner flange This insulating gasket has six holes which if necessary can be modified as shown on the drawing on the right D5242 Fig 2 Verify that the installed burner...

Page 6: ...leakage of the valve PRIMING THE PUMP Start the burner and wait for the priming Should lock out occur prior to the arrival of the fuel await at least 20 seconds before repeating the operation A filte...

Page 7: ...OX see fig 4 To remove the control box 1 from the burner Unscrew the fissing screws on the burner cover and remove it Unscrew the fissing screws 2 on the plate and remove the control box 1 Screw the t...

Page 8: ...uring ignitions at low temper atures PUMP PRESSURE 12 bar the pump leaves the factory set at this value 14 bar improves flame retention it is therefore suitable for ignitions at low temperatures COMBU...

Page 9: ...ting the number of turns AIR DAMPER ADJUSTMENT fig 7 The mobile air damper A operated by the jack B as sures the complete opening of the air intake The regulation of the air rate is made by adjusting...

Page 10: ...s discon nected or broken FAILURE DETECTION ON HEATING DEVICE Only for type 447T1 The plug fitted in the panel is placed in the position corre sponding to Resistance ON see fig 8 When the remote contr...

Page 11: ...ve same openings suitable for the passage of air nec essary for combustion To be sure about this you have to control the smoke number of exhaust gas with all the windows and doors closed If in the pla...

Page 12: ...tion areas and in the combustion product waste pipe Clean the filter in the oil suction line and in the pump Check for correct fuel consumption Check that the burner electrical connections are correct...

Page 13: ......

Page 14: ...20013743 CN Technical Assistance Centre Assistance Centre Maintenance Contract...

Page 15: ...C 2006 95 EC 2006 42 EC O EN 60529 IP 40 7 1 447T1 28 60 kW 2 3 5 kg h 20 C 4 6 mm2 s 1 5 E Hi 11 86 kWh kg 230V 10 50Hz 0 75A 2800 rpm 294 rad s 4 F 8 kV 16 mA 7 15 bar 0 185 kW 1 3 7 1 2 3 4 5 6 7 8...

Page 16: ...20013743 2 CN 2 1 2 4 1 2 1 3 0 8 0 0 4 mbar 2 3 4 5 kg h 25 30 60 kW D5226 35 40 45 50 55 0 2 0 6 2 3 270 122 224 130 33 4 5 80 228 11 175 D4646 180 75 72 150 4 5...

Page 17: ...3 20013743 CN 9 1 6 6 D5242 2 2 D5572 S7384...

Page 18: ...N 0 4 bar 30 cm Hg 20 H L 8 mm 10 mm 0 5 1 1 5 2 10 20 40 60 20 40 80 100 A 3 A H L 8 mm 10 mm 0 0 5 1 1 5 2 3 3 5 35 30 25 20 15 8 6 100 100 100 90 70 30 20 H 4 m H H 4 m 0 1 m D5219 D5220 D5199 H L...

Page 19: ...5 20013743 CN 1mm 4 1 2 1 2 1 2 1 D4677 A 531SE C E F FR P E H I M PE R TL TS Y 4...

Page 20: ...Steinen H Q Danfoss H 60 80 12 bar 14 bar 5 12bar 0 75 GPH 2 5 GPH bar kg h 4 0 60 60 80 11 2 3 1 5 2 0 65 60 80 12 2 6 2 2 2 0 75 60 12 3 0 2 5 2 5 0 85 60 12 3 4 3 3 1 00 60 12 4 0 4 4 5 1 10 60 12...

Page 21: ...7 20013743 CN 6 6mm 2 1 CO2 CO2 3 1 3 7 A B C D D A 0 1 2 3 6 D5551 D C D5555 D A B 6 7 4...

Page 22: ...20013743 8 CN 2 Resistance OFF 8 LED 447T1 Resistance ON 8 LED 1 LED 2 LED Resistance OFF 9 3 10 LED S7059 531SE B S7060 LED 8 9 A 2 2 5 mm 4 0 3 mm D5230 A 10...

Page 23: ...9 20013743 CN 120 D5329 120 12 12 5...

Page 24: ...20013743 10 CN CO2 CO ppm NOx ppm...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...I 37045 Legnago VR Tel 39 0442 630111 http www riello it http www rielloburners com Manufacturing site Riello Heating Equipment Shanghai CO LTD No 388 Jinbai Road Jinshan Industrial Zone 201506 Shang...

Reviews: