8
GENERAL INFORMATION
1.7
Technical specifications
DESCRIPTION
INSIEME EVO 25
Device type
Low temperature
central heating
B23
Fuel
Heating fuel oil
(light oil)
Maximum rated heat input at furnace referred to HVC (LCV)
27,5 (26)
kW
Useful (rated) heat output
25
kW
Maximum useful heat output
P4
(60-80°C)
24,7
kW
30% heat output
P1
with return at 37°C
7,4
kW
Efficiency class in central heating mode
B
Seasonal energy efficiency in central heating mode
ηs
86
%
Efficiency at rated heat output in high temperature
mode referred to HCV
η4
Pn (60-80°C)
89,6
%
Efficiency at 30% rated heat output in low
temperature mode referred to HCV
η1
with return at 37°C
91
%
Heat loss in standby mode
Pstby
44
W
Combustion efficiency referred to LCV
96
%
Annual energy consumption
QHE
82,6
GJ
Noise level (sound power)
LWA
60
dB(A)
Emissions at maximum heat input
NOx
(referred to HCV)
170
mg/kWh
CO2
12,5
%
CO w.a. <
20
ppm
Flue gas T
At Pn (60-80°C)
110
°C
Smoke scale
< 0,5
Flue gas mass flow rate
10,0
g/s
Maximum working pressure
3
bar
Safety thermostat trip temperature
100
°C
Maximum operating temperature
55-82
°C
Minimum return temperature
37
°C
Boiler water capacity
30
l
Turbulators
19
Volume of expansion vessel (CH)
8
l
Precharge of expansion vessel (CH)
1,5
bar
Index of protection
X0D
IP
Power supply
230 V - 50 Hz
Absorbed power supply (max)
184
W
Consumption at full load
Elmax
131
W
Consumption at part load
Elmin
39
W
Electrical consumption in standby mode
P sb
12
W
LCV: Lower calorific value of fuel
HCV: Higher calorific value of fuel
Test conditions:
− Room temperature 22°C
− Atmospheric pressure 1018 mbar