Installation
5.4
Working position
5.5
Boiler fixing
Put on the flange 1)(Fig. 5) the screw and two nuts.
Fix the flange 1)(Fig. 6) to the boiler door 4) using screws 2)
and (if necessary) the nuts 3) interposing the insulating gas-
ket 5).
WARNING
The burner is designed to operate only in the po-
sitions
1
, and
3
(Fig. 4).
Installation
1
is preferable, as it is the only one that
allows performing maintenance operations as de-
scribed in this manual. Installations
2
,
3
and
4
al-
low working operations but not maintenance with
hooking to the boiler.
DANGER
Any other position could compromise the correct
operation of the appliance. Installation
5
is forbid-
den for safety reasons.
D4618
1
2
3
4
5
Fig. 4
E9095
1
Fig. 5
WARNING
The seal between burner and boiler must be
airtight.
5
1
E9094
2
4
3
Fig. 6