Combustion head setting
The setting of the combustion head depends exclusively on the
maximum burner delivery at which it will be operating.
Turn screw 4) (Fig. 13) until the notch shown in diagram (Fig. 14)
is level with the front surface of flange 5) (Fig. 13).
Example:
RL 190/M, maximum light oil delivery = 150 kg/h
Diagram (Fig. 14) indicates that for a delivery of 150 kg/h the
RL 190/M Model requires the combustion head to be set to ap-
prox. three notches, as shown in (Fig. 13)
Fig. 13
D462
D1985
Fig. 14
Notches no.
Light oil delivery in 2nd stage
kg/h