List of parameters PME71.901...
The following pages have the Menus and the list of parameters
for setting up the LCD AZL 2... Display for the LME 71... control
box with PME 71.901...
The values shown in the “Factory setting” column, in the table be-
low, are only given as a guide (Control box not programmed).
10
List of parameters PME71.901...
Parameter
Modification
Values interval
Resolution
Factory
setting
Password
reading
level to
level
Password
writing level
to level
Nr.
Description
Min.
Max.
000
Internal parameter
41
Password for heating engineering (4 characters) Modification
xxxx
xxxx
---
---
---
OEM
42
Password OEM (5 characters)
Modification
xxxxx
xxxxx
---
---
---
OEM
60
Backup/Restore
Modification
Restore
Backup
---
---
---
SO
100
General notes
102
Identification date
Reading only
---
---
---
---
Info
---
103
Identification number
Reading only
0
9999
1
0
Info
---
113
Burner identification
Modification
x
xxxxxxxx
1
burnErId
Info
SO
123
Step control min output.
Modification
1%
10%
0.1
2
SO
SO
140
Displaying the unit operation mode and display-
ing AZL2...
1 = standard (program phase)
2 = flame 1 (QRA.../ION)
3 = flame 2 (QRB.../QRC...) ® not used
4 = output active (output value)
Modification
1
4
1
4
SO
SO
164
Number of resettable start-ups
Resettable
0
999999
1
0
Info
Info
166
Total number of start-ups
Reading only
0
999999
1
0
Info
---
170.00
Switching cycles relay contact K12
Reading only
0
999999
1
0
Info
---
170.01
Switching cycles relay contact K11
Reading only
0
999999
1
0
Info
---
170.02
Switching cycles relay contact K2
Reading only
0
999999
1
0
Info
---
170.03
Switching cycles relay contact K1
Reading only
0
999999
1
0
Info
---
171
Max. relay commutation cycles
Reading only
0
999999
1
0
Info
---
200
Burner Control
224
Air pressure switch special time
Modification
0s
13.818 s
0.294 s
13.818 s
SO
OEM
225
Pre-purging time - 2.1 seconds
Modification
0s
1237 s
4.851 s
29.106 s
SO
OEM
226
Spark pre-ignition time
Modification
1.029 s
37.485 s
0.147 s
6.174 s
SO
OEM
230
Interval: End of the safety time - resetting of the
load regulator
Modification
3.234 s
74.97 s
0.294 s
9.408 s
SO
OEM
234
Post-purging time
Modification
0s
1237 s
4.851 s
19.404 s
SO
OEM
235
Air pressure switch input
0 = inactive
1 = active
Modification
0
1
1
0
SO
OEM
240.00
Repetitions meter
Limit value of flame loss during operation
Modification
0
2
1
0
SO
OEM
240.01
Repetitions meter
Limit value of No flame at the end of the safety
time
Modification
0
1
1
1
SO
OEM
241.00
Valves Seal Control
0 = OFF
1 = ON
Modification
0
1
1
1
SO
OEM
241.01
Valves Seal Control
0 = during pre-purging
1 = during post-purging
Modification
0
1
1
1
SO
OEM
241.02
Valves Seal Control
0 = according to P241.01
1 = during pre-purging and post-purging
Modification
0
1
1
0
SO
OEM
242
Evacuation of valve seal control test area
Modification
0s
2.648 s
0.147 s
2.648 s
SO
OEM
243
Atmospheric pressure valve seal control time
test
Modification
1.029 s
37.485 s
0.147 s
10.290 s
SO
OEM
244
Filling the valve seal control test area
Modification
0s
2.648 s
0.147 s
2.648 s
SO
OEM
245
Gas pressure valve seal control time test
Modification
1.029 s
37.485 s
0.147 s
10.290 s
SO
OEM
257
Post-ignition time -0,3 seconds
Modification
0s
13.23 s
0.147 s
2.205 s
SO
OEM
400
Ratio control (operation)
403.00
Fan speed: Ignition load speed (P0)
Modification
800 rpm
900 rpm
10 rpm
3000 rpm
SO
SO
403.01
Fan speed: Low flame speed (P1)
Modification
800 rpm
900 rpm
10 rpm
1200 rpm
SO
SO
403.02
Fan speed: High flame speed (P2)
Modification
800 rpm
900 rpm
10 rpm
5700 rpm
SO
SO
500
Ratio control
503.00
Speed without PWM fan flame: Standby speed
Modification
0 rpm
9000 rpm
10 rpm
0 rpm
SO
SO