72
TECHNICAL ASSISTANCE SERVICE
3 .13
Positioning the electrodes
3 .14
Cleaning the condensate drain and siphon
Correct positioning of the ignition electrode and flame
detection sensor is essential for efficient ignition and
combustion.
With the burner removed, verify the state of wear and
the positioning of the ignition electrode and flame de-
tection sensor according to the figure below. Replace if
damaged or worn.
9
It is essential to respect the dimensions in the fi-
gure.
8.2
4.0
16.3
− Remove the front panel from the boiler and loca-
te the condensate drain siphon (1)
− Remove the spring clip (2), detach the corrugated
condensate drain hose, and remove the siphon.
Unscrew the two caps (3) to disassemble the
siphon
− Remove the float (4) and clean all internal com-
ponents
On completion of cleaning, follow the above steps in the
reverse order to refit all removed parts.
2
1
3
4
3