12 Manufacturer’s Guarantees

12.1 The Manufacturer guarantees conformity of the Detector to the 

requirements of its technical  specification, provided that conditions of 
transportation, storage, assembling and operation are observed.

12.2 The guaranteed shelf life is 63 months since the date of manufacturing 

the detector.

12.3 The guaranteed service life is 60 months since the date of commissioning 

within the storage period guaranteed.

12.2 If non-conformity of the Detector to technical requirements is detected 

during the guaranteed period, provided that rules of operation are observed, it 
shall be repaired by the Manufacturer.

Note:

 The guaranteed period for the Detectors is not applied to the power-

supply batteries.

13 Acceptance and Рacking Сertificate 

Security wireless inertia detector «GRAN-RK», lot No _____________ 

has been manufactured in accordance with current technical documentation is 
classified as fit for operation and is packed by «RIELTA» JSC.

Person responsible for acceptance and packing

    Representative of QCD _________________      __________________

                                                           

Date, month, year  

  

  Mod 1 от 08.06.15 
                

Э00101                      

                        V 3.2

«RIELTA» JSC, www.rielta.ru
Chapaeva Str. 17, Saint Petersburg 197101, rielta@rielta.ru

Tel./fax +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, support@

rielta.ru

Made in Russia

Table  4

LED Indication

Communication Quality 

Appraisal

Recommendations 

Color

Mode

Green

Three blinks

Excellent

Installation of the Detector 

recommended

Green

Two blinks

Good

Green

One blink

Communication 

presents

Choose another place or 

use the repeater *)

Red

Four blinks

No communication

*) – «Ladoga-BRSS-RK-RTR» or «Ladoga BRSS-RK-RTR» vers. 1

10 Installation

10.1 Install the Detector in the place, where the radio communication quality 

is apprised as «Excellent» or «Good».

10.2 The place of installation should be protected against accident mechanical 

interferences: impacts, vibration. 

10.3 Fasten the base to the mounting surface. 
The main method of the Detector installation is fastening of the base to the 

mounting surface is by means of double-sided tape. For the reliable Detector 
mounting, fulfill the following steps:

- check, that the mounting surface is flat, dry and clean;
- put off protective film from the working surface of the double-sided tape;
- fix tightly the Detector to the mounting place and hold it down for 2-3 s.
To ensure removal control, the Detector is fastened to the secured object 

by means of screw through the Detector openable hole (6) in the base of the 
Detector.

10.4 Install the cover with the PCB to the base.
10.5 After the Detector mounting, check the «Interference» indication absence 

during 1-2 minutes.

Attention!

 Do not leave the Detector energized for the long time while the 

repeater is powered off. It will save the battery life.

11 Storage and Transportation

11.1 The storage room shall be free from current-conducting dust, acid vapors, 

alkali and gases that cause corrosion and destroy insulation.

11.2 The Detector packed for shipping shall be stored no more than 3 months. 

The shipping package shall be free from leaks and dirt. 

11.3 In case of storage over 3 months, the Detector should be unpacked.
11.4 Factory-packed detector can be shipped by any transport means in 

covered vehicles (in railway cars, trucks, sealed heated compartments of 
aircraft, holds etc). 

11.5 The Detector in the package during transportation is resistant to:
a) transport jolting with the acceleration 30 m/s² with impact frequency from 

10 to 120 impacts/s or 15000 impacts with the same acceleration;

b) the ambient temperature minus 50 … +50 °С;
c) relative air humidity  (95 ± 3) % at the ambient tempe35 °С.

11.6 After transportation under the conditions different to exploitation 

conditions, the Detector should be ready to operate after a maximum of six hours.