12 Manufacturer’s Guarantees
12.1 The Manufacturer guarantees conformity of the Detector to the
requirements of its technical specification, provided that conditions of
transportation, storage, assembling and operation are observed.
12.2 The guaranteed shelf life is 63 months since the date of manufacturing
the detector.
12.3 The guaranteed service life is 60 months since the date of commissioning
within the storage period guaranteed.
12.2 If non-conformity of the Detector to technical requirements is detected
during the guaranteed period, provided that rules of operation are observed, it
shall be repaired by the Manufacturer.
Note:
The guaranteed period for the Detectors is not applied to the power-
supply batteries.
13 Acceptance and Рacking Сertificate
Security wireless inertia detector «GRAN-RK», lot No _____________
has been manufactured in accordance with current technical documentation is
classified as fit for operation and is packed by «RIELTA» JSC.
Person responsible for acceptance and packing
Representative of QCD _________________ __________________
Date, month, year
Mod 1 от 08.06.15
№
Э00101
V 3.2
«RIELTA» JSC, www.rielta.ru
Chapaeva Str. 17, Saint Petersburg 197101, rielta@rielta.ru
Tel./fax +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, support@
rielta.ru
Made in Russia
Table 4
LED Indication
Communication Quality
Appraisal
Recommendations
Color
Mode
Green
Three blinks
Excellent
Installation of the Detector
recommended
Green
Two blinks
Good
Green
One blink
Communication
presents
Choose another place or
use the repeater *)
Red
Four blinks
No communication
*) – «Ladoga-BRSS-RK-RTR» or «Ladoga BRSS-RK-RTR» vers. 1
10 Installation
10.1 Install the Detector in the place, where the radio communication quality
is apprised as «Excellent» or «Good».
10.2 The place of installation should be protected against accident mechanical
interferences: impacts, vibration.
10.3 Fasten the base to the mounting surface.
The main method of the Detector installation is fastening of the base to the
mounting surface is by means of double-sided tape. For the reliable Detector
mounting, fulfill the following steps:
- check, that the mounting surface is flat, dry and clean;
- put off protective film from the working surface of the double-sided tape;
- fix tightly the Detector to the mounting place and hold it down for 2-3 s.
To ensure removal control, the Detector is fastened to the secured object
by means of screw through the Detector openable hole (6) in the base of the
Detector.
10.4 Install the cover with the PCB to the base.
10.5 After the Detector mounting, check the «Interference» indication absence
during 1-2 minutes.
Attention!
Do not leave the Detector energized for the long time while the
repeater is powered off. It will save the battery life.
11 Storage and Transportation
11.1 The storage room shall be free from current-conducting dust, acid vapors,
alkali and gases that cause corrosion and destroy insulation.
11.2 The Detector packed for shipping shall be stored no more than 3 months.
The shipping package shall be free from leaks and dirt.
11.3 In case of storage over 3 months, the Detector should be unpacked.
11.4 Factory-packed detector can be shipped by any transport means in
covered vehicles (in railway cars, trucks, sealed heated compartments of
aircraft, holds etc).
11.5 The Detector in the package during transportation is resistant to:
a) transport jolting with the acceleration 30 m/s² with impact frequency from
10 to 120 impacts/s or 15000 impacts with the same acceleration;
b) the ambient temperature minus 50 … +50 °С;
c) relative air humidity (95 ± 3) % at the ambient tempe35 °С.
11.6 After transportation under the conditions different to exploitation
conditions, the Detector should be ready to operate after a maximum of six hours.