The unit can be tested with CO by using one of the kits that comes with CO either in a glass phial or aerosol can.
Follow the instructions on the kit. When it senses the CO
,
it will have a Pre-Alarming status, please refer to
table A for all detailed alarming indicators:
CO Alarm Response
CO Level
(ppm)
Pre-Alarming status:
(Red LED only without
beep)
Response Time
(MIN)
Alarming
Red LED Indictor
Alarming Horn
0 ppm
Off
N/A Off
Off
50 ppm
2 Flashes / 4 Seconds
60-90
4 Flashes / 4 Seconds
4 Beeps / 4 Seconds
100 ppm
3 Flashes / 4 Seconds
10-40
4 Flashes / 4 Seconds
4 Beeps / 4 Seconds
300 ppm
4 Flashes / 4 Seconds
<3
4 Flashes / 4 Seconds
4 Beeps / 4 Seconds
(Table A)
HOW TO SET THE WIRELESS INTERCONNECTION FUNCTION
DIP switch function:
The 1~4numeric is for ID coding, total 16 coding (refer
to
TABLE1
). ID 0 (coding 0000) is a public ID, it can communicate with other all
other 15
IDs. Except ID0, the devices can communicate each other only in same ID
coding.
The 5 numeric is for repeater function.
When being slid ON, the repeater function works. Repeater function: When the device receives
emission signal and gives alarm, it will emit signal
immediately to drive other units alarming. It
is also a
relay station
of wireless
signal to
form a
wireless
alarm
network with
relay
transmit. The
emit distance
is 30m in
house area.for the repeater setting the right diagram is for your reference.
FOLLOW THE ID SETUP STEPS
1.
Remove the battery.
2.
Press and hold the button for a minimum of 10 seconds.
3.
Find the 5-position dipswitch located on the back of each device.
4.
Select one of the units. You will define the ID of your system by positioning the switches of the dipswitch in a random
pattern. The ID will need to be the same for each alarm. This ID will differentiate your alarm system from similar systems
nearby.(refer to
TABLE 1
)
5.
Using a pen or pencil, change the switches in each of the wireless devices to match the pattern you selected in step 3.
Ensure that the sequence is not reversed.
6.
Insert a 9-volt battery to compartment.
NOTE POLARITY OF CONNECTIONS.
The alarms only read the ID that has
been set when they are first supplied power. Any changes to the switch after the unit is powered will not be recognized, and
TABLE1
1~4 ID
1~4
ID
0000 0
1000
8
0001 1
1001
9
0010 2
1010
10
0011 3
1011
11
0100 4
1100
12
0101 5
1101
13
0110 6
1110
14
0111 7
1111
15