14
Laser Seam Tracking System for Welding Automation. RF627Weld Series
RF627Weld [Revision 1.1.1] 03.08.2020
12. Connection procedure
System with controller
System without controller *
#
Description
#
Description
1
Connect the scanner to the controller using a
UNITRONIC® LiYCY (TP) cable.
1
Connect the scanner to the PC using a
UNITRONIC® LiYCY (TP) cable compressed to
RJ-45 Ethernet and two power wires.
2
Connect the scanner controller to the robot
controller using an RJ-45 Ethernet cable.
2
Connect the PC to the robot controller using an
RJ-45 Ethernet cable.
3
Connect the scanner controller to 220V AC
using a power cable.
3
Connect the scanner to the power supply unit
(red wire is a "plus" of the power supply unit,
brown wire is a "minus" of the power supply unit).
4
Switch on the scanner controller by pressing
the power button.
4
Make network settings as described in the
previous section.
5
Supply power to the system (9...30 V, or 12...39
V for scanners with blue laser).
NOTE 1:
Within 8 seconds after powering on, the FPGA firmware is booting and
the Ethernet interface is initializing (the red LED blinks). After that, the system is ready to
operate (the green LED blinks).
NOTE 2:
To turn off the system, press the power button on the controller, or turn off
the power supply (for the system without controller).
13. Setting parameters of the scanner
To configure parameters of laser scanners RF627Weld, you can use both the web
page or the Riftek Lamia software. For more information, read sections
14. Web page
The web page is intended to check the operation and configure parameters of the
scanner. To access the web page, enter the IP address of the scanner into the address bar
of the web browser:
The web page contains four areas (shown above):
1. Scanner status indicators.
2. Parameterization tabs.