15.4. "SEARCH" tab. Search, connection and settings
15.4.1. Search for scanners
To start searching for the scanners, click the
SEARCH
button, or use the keyboard
shortcut
Ctrl + F
. In addition, you can enable the
Search on start
option in the
Settings
window in order to start the search automatically when you start the program.
When the scanner is detected, the program activates the connection panel:
This panel displays the scanner series (RF627), serial number (180003), and IP
address (192.168.1.30). To view additional information, click on the "
i
" icon:
Information about the scanner:
Address
IP address of the scanner.
Z Base
Base distance, mm.
Z Range
Measurement range, mm.
X SMR
The range by X coordinate at the beginning of the working range by Z, mm.
X EMR
The range by X coordinate at the end of the working range by Z, mm.
МАС
МАС address.
Firmware
Firmware version.