RF627Weld [Revision 1.1.1] 03.08.2020
Laser Seam Tracking System for Welding Automation. RF627Weld Series
7
Designations:
1. RJ-45 Ethernet connector.
2. Wi-Fi / Bluetooth antenna.
3. USB 2.0 connectors.
4. Scanner connector.
5. Power button.
6. Power connector.
Since the controller has the Wi-Fi antenna, the user can connect to the controller via
a remote desktop or via the SSH protocol by creating an access point.
The controller comes optional. Instead of the controller, the customer can use a PC with Riftek
Lamia software installed and a power supply unit.
Technical characteristics and overall dimensions are given in section
5.4. Cables
The system comes with three cables:
1. UNITRONIC® LiYCY (TP) cable.
2. RJ-45 Ethernet cable.
3. Power cable.
5.4.1. UNITRONIC® LiYCY (TP) cable
The UNITRONIC® LiYCY (TP) cable is used to connect the scanner to the controller.
Designations:
Name
Description
Х1
Binder 423 99 5456 15 16
Х2
RJ-45
1
LAPP KABEL UNITRONIC® LiYCY (TP) cable, #0035150, 8x2x0.14