RF627Weld [Revision 1.1.1] 03.08.2020
Laser Seam Tracking System for Welding Automation. RF627Weld Series
13
ATTENTION!
The scanner and controller must be grounded. Static electricity may cause the failure of electronic
components. To ground the controller, use the DIN rail.
10. Ethernet interface
Profiles are transferred between the scanner and the controller over the UDP
protocol, the structure of packets is described in the Developer Guide. Download link:
https://riftek.com/media/documents/rf627/soft/RF627_Software_Tools_eng.pdf
11. Network configuration
All scanners are shipped with the following network configuration unless otherwise
specified in the order:
·
Autonegotiation of connection speed (100/1000 Mbps)
·
IP address of the scanner: 192.168.1.30
·
Subnet mask: 255.255.255.0
·
Gateway: 192.168.1.1
·
Host IP address (device that receives profiles): 192.168.1.2
·
Host port that receives data: 50001
·
HTTP connection port (for connecting a browser): 80
·
Service port of the scanner: 50011
·
Ethernet/IP service port: 44818
If the order does not include a controller, it is necessary to configure the network
card of the PC in the 192.168.1.* address space. An example:
NOTE:
Ethernet Jumbo frames are not supported by the scanner.