Parameter
Factory value
Description
Brightness
threshold (%)
10
The level of profile detection on the image. Increasing this parameter
allows to decrease the influence of image noise. Range of values:
0...100%. If the value is "100%", the image is not processed.
Filter width
25
The width of the filter for primary processing of image points. Valid
values: from 1 to 25.
Mode
High accuracy
Two modes are available: High accuracy and Welding. The Welding
mode is intended to be used with the scanners installed on welding
robots and operating under conditions of strong light interference.
Noise reduction
OFF
Removing unstable points from the profile. The points are considered
unstable if they are not detected at least once in 128 profiles in a row.
Median filter
width
Disabled
The size (number of points) of the sliding window of the median filter.
Valid values: 0, 3, 5, 7, 9, 11, 13, 15. If the value is "0", the filter is
disabled.
Bilateral filter
width
Disabled
The size (number of points) of the sliding window of the bilateral
smoothing filter. Valid values: 0, 3, 5, 7, 9, 11, 13, 15. If the value is
"0", the filter is disabled.
Peak selection
mode
Max intensity
The algorithm for determining the peak brightness in the image column
to obtain the profile point. It is used to suppress false images resulting
from multiple reflections on complex profiles.
Modes:
Max intensity – Selecting the peak with the greatest brightness.
First – Selecting the first peak in the column above.
Last – Selecting the last peak in the column above.
Index 2…6 – Selecting the peak with the corresponding number
.
Profile flip Х
OFF
Flip the profile along the X axis of the scanner.
Profile flip Z
OFF
Flip the profile along the Z axis of the scanner.
15.4.3.2.6. "Laser" panel
Parameter
Factory value
Description
Laser
ON
Turn on / off the laser.
Laser level (%)
10
Laser output power level. Range of values: 0...100%.
15.4.3.2.7. "General" panel
Parameter
Factory value
Description
Save log
ON
Recording information about the operations performed.