RIGOL
2-70
DG900 Programming Guide
frequency to low frequency. When the start frequency is equal to the stop frequency, the signal
generator outputs at the fixed frequency.
When [:SOURce[<n>]] or [<n>] is omitted, the system sets the related parameters of CH1 by default.
The Sine, Square, Ramp, and Arbitrary waveform can generate the sweep output. The range of the
stop frequency <frequency> differs for different sweep waveforms.
The start frequency, stop frequency, center frequency and frequency span fulfills the following
equations.
|)
(|
stop
start
center
F
F
F
+
=
;
|)
(|
start
stop
span
F
F
F
−
=
Wherein,
center
F
——center frequency;
span
F
——frequency span;
start
F
——start frequency;
stop
F
——stop frequency.
The generator will restart to sweep and output from the specified "Start Frequency" after the "stop
frequency" is modified. In large-scale sweep, the amplitude characteristic of the output signal might
change.
Return Format
The query returns the stop frequency in scientific notation, with 7 effective digits. For example,
9.02 (the stop frequency is 900 Hz).
Example
:SOUR1:FREQ:STOP 900 /*Sets the stop frequency of the sweep function of CH1 to 900 Hz.*/
:SOUR1:FREQ:STOP? /*Queries the stop frequency of the sweep function of CH1 and the query
returns 9.02.*/
:SOURce:FUNCtion
Command List:
[:SOURce[<n>]]:FUNCtion:DUALTone:CENTERFreq
[:SOURce[<n>]]:FUNCtion:DUALTone:FREQ1
[:SOURce[<n>]]:FUNCtion:DUALTone:FREQ2
[:SOURce[<n>]]:FUNCtion:DUALTone:OFFSETFreq
[:SOURce[<n>]]:FUNCtion:PRBS:BRATe
[:SOURce[<n>]]:FUNCtion:PRBS:DATA
[:SOURce[<n>]]:FUNCtion:PULSe:DCYCle
[:SOURce[<n>]]:FUNCtion:PULSe:PERiod
[:SOURce[<n>]]:FUNCtion:PULSe:TRANsition[:BOTH]
[:SOURce[<n>]]:FUNCtion:PULSe:TRANsition:LEADing
[:SOURce[<n>]]:FUNCtion:PULSe:TRANsition:TRAiling
[:SOURce[<n>]]:FUNCtion:PULSe:WIDTh
[:SOURce[<n>]]:FUNCtion:RAMP:SYMMetry
[:SOURce[<n>]]:FUNCtion:RS232:BAUDrate
[:SOURce[<n>]]:FUNCtion:RS232:CHECKBit
[:SOURce[<n>]]:FUNCtion:RS232:DATA
Summary of Contents for DG952
Page 2: ......
Page 168: ......
Page 181: ...Chapter 4 Programming Examples RIGOL DG900 Programming Guide 4 7 ...
Page 185: ...Chapter 4 Programming Examples RIGOL DG900 Programming Guide 4 11 ...
Page 187: ...Chapter 4 Programming Examples RIGOL DG900 Programming Guide 4 13 ...
Page 199: ...Chapter 4 Programming Examples RIGOL DG900 Programming Guide 4 25 ...
Page 200: ......