NEGative: The selected data line outputs low level signal (CMOS level) when the
control source is turned on.
Return Format
The query returns POSITIVE or NEGATIVE.
Examples
:TRIG:OUT:POLA D1,NEGAtive /*Sets the D1 trigger output signal to
low level.
:TRIG:OUT:POLA? D1 /*Queries the D1 trigger output signal. The
query returns NEGATIVE.*/
4.13.7
:TRIGger:OUT:SOURce
Syntax
:TRIGger:OUT:SOURce
<
d>,<source>
:TRIGger:OUT:SOURce?
<
d>
Description
Sets or queries the control source of the trigger output function of the specified data
line.
Parameter
Name
Type
Range
Default
<d>
Discrete
{D1|D2|D3|D4}
D1
<source>
Discrete
{CH1|CH2|CH3}
CH1
Remarks
You can select any one of CH1, CH2, and CH3 as the control source of trigger output.
Return Format
The query returns the name of the control source selected, for example, CH1.
Examples
:TRIG:OUT:SOUR D1,CH1 /*Sets the control source of D1 trigger
output to CH1.*/
:TRIG:OUT:SOUR? D1 /*Queries the control source of D1 trigger
output. The query returns CH1.*/