15
INSTALLATION INSTRUCTION
Air regulator installation and operation
1.
Firmly tight and seal the copper air hole at IN and OUT terminal. By high pressure rubber tube firmly.
2.
Tight and seal the meter with meter face rubber tube.
3.
Fix the connecting shelf with screw as the regulator position.
4.
Get down the plastic screw and fix the regulator on the shelf.
5.
Turn on the air valve, turn up the pressure adjusting knob, Turn the pressure to rated value (meter
inside shows Kgf/cm
2
), and then put down the knob (+ means increasing pressure,
_
means
decreasing pressure).
6.
Scale of the meter is as follow. The value in the picture is 6kg.
7.
If the water in the gas filtering bottle is too much, please turn on the water valve to let the water go
out.
Regulator installation
1
Pressure adjustment knob
2
Connecting shelf
3
Copper air mouth
4
Pressure meter
5
Air filting bottle
6
Air pipe
7
Drain knob
8
Electromagnetic air-in
9
Air in
10
Air out
11
Pressure meter face