background image

  Keep off combustible when cutting. 

  Keep hot workpiece after cutting away from flammable gas. 

  Do move away the combustible around when cut the dooryard, ground and wall,. 

  The wire connection of base metal should be as close to the cutting place as possible. 

  Never cut those facilities with gas pipe or airtight slot.   

  Put fire extinguisher around the cutting area to prevent fire.   

  The gas and fumes are harmful to health, please wear protective device 

according to regulations. 

  Wear exhaust equipment and breathe preventive facilities to prevent gas poisoning or choke.   

  Use suggested part exhaust equipment and breathe preventive facilities to prevent hurt or 

poisoning by gas and other powder, please.   

  To prevent oxygen-deficiency, air out the gas-filled room which is full of CO

2

 and argon on the 

bottom, when operating on trunks, boilers, cabins, etc.     

 

Please accept the supervisor’s inspection when operating in narrow space. Air the room and 

wear breathe preventive facilities.   

  Never operate in degrease, washing or spray space.   

  Using breathe preventive facilities when cut shielded steel for it will cause poisonous dust and 

gas.   

 

The arc, spark, residue and noise are harmful to health, please wear 

protective appliance.   

  Eye protection against arc is recommended when cutting or supervise cutting.   

  Please wear preventive spectacles.   

  Operator

’s gloves, operator’s goggles, long sleeve clothes, leather apron, and other standard 

protection equipments must be worn for cutting operation. 

  A screen to protect other people against the arc must be set in the cutting place.   

  Please follow the notes below to avoid gas cylinder toppling over or 

broken. 

  Use the gas cylinder correctly.   

  Use the equipped or recommended gaseous regulator.   

  Read the manual of gaseous regulator carefully before using it, and pay attention to the safety 

Summary of Contents for LGK 100IJ

Page 1: ...3 LGK 100IJ CUTTING MACHINE USER MANUAL...

Page 2: ...rt or property lose if it is not followed The words after this sign means there is potential risk which may cause equipment fault or break if it is not followed Version Version YF TAE 0099 A0 Released...

Page 3: ...L PARAMETERS TABLE 12 PANELFUNCTION INSTRUCTION 13 INSTALLATION INSTRUCTION 14 INSTALLATION INSTRUCTION 15 NOTES OR PREVENTIVE MEASURES 16 QUESTIONS TO BE RUN INTO DURING CUTTING 17 MAINTENANCE 18 NOT...

Page 4: ...cause choke Spark and hot workpiece after cutting may cause fire Bad connected cable may cause fire Incompletion connection of workpiece side circuit may cause fire Never cut on the case of tinder st...

Page 5: ...s below to avoid electric shock Keep away from any electric parts Earth the machine and workpiece by professional personnel Cut off the power before installation or checking and restart 5 minutes late...

Page 6: ...en operating on trunks boilers cabins etc Please accept the supervisor s inspection when operating in narrow space Air the room and wear breathe preventive facilities Never operate in degrease washing...

Page 7: ...checking the wire feeding is normal or not or the shooting wire may stab your eyes and face Keep your eyes face or other naked parts away from the end of torch when feeding the wire manually or pressi...

Page 8: ...cemaker or audiphone f Equipments for adjustment and measurement g Anti disturb capability of other used equipments Users should ensure these equipments and the environment are compatible which may ne...

Page 9: ...rm strong plasma arc It has the functions of arc initiation current arc stop current cutting current basic value current current ascending time current descending time gas delay time continuous adjust...

Page 10: ...Hz 50 60 Rate input current A 23 1 21 1 19 9 No load voltage V 276 301 319 Current Range A 23 100 Rate output voltage V 89 2 120 Duty cycle 60 Efficiency 85 No load loss W 80 Power factor 0 93 Insula...

Page 11: ...er heat abnormal indicator 3 over current Abnormal indicator 4 Current adjustment knob 5 Positive output terminal 6 Pilot arc output terminal 7 Torch switch socket 8 Gas electricity system output The...

Page 12: ...e joint with hoop or other ways in case of gas leaking Dry gas with suitable pressure and flow should be supplied If your air source cannot meet above requirements you should consider using sole compr...

Page 13: ...lve turn up the pressure adjusting knob Turn the pressure to rated value meter inside shows Kgf cm2 and then put down the knob means increasing pressure _ means decreasing pressure 6 Scale of the mete...

Page 14: ...is adequately ventilated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to watch the max duty current Response to the selected du...

Page 15: ...d input cable is too long C Output current is not up to the rated value When power voltage departs from the rated value it will make the output current not matched with rated value when voltage is low...

Page 16: ...If scale and loose are found please give a good polish to them then connect them again tightly 4 Avoid water and steam enter into inter machine if they enter into machine please dry inter machine the...

Page 17: ...ontrol wire of gun broken or switch broken 3 Control circuit is broken Contact factory Abnormal indicator is lit meter is normal fan is normal 1 High pressure device is broken 2 IGBT is broken 3 Recti...