background image

15 

INSTALLATION INSTRUCTION 

Air regulator installation and operation 

1. 

Firmly tight and seal the copper air hole at IN and OUT terminal. By high pressure rubber tube firmly. 

2. 

Tight and seal the meter with meter face rubber tube. 

3. 

Fix the connecting shelf with screw as the regulator position. 

4. 

Get down the plastic screw and fix the regulator on the shelf. 

5. 

Turn on the air valve, turn up the pressure adjusting knob, Turn the pressure to rated value (meter 
inside  shows  Kgf/cm

2

),  and  then  put  down  the  knob  (+  means  increasing  pressure, 

means 

decreasing pressure). 

6. 

Scale of the meter is as follow. The value in the picture is 6kg. 

7. 

If the water in the gas filtering bottle is too much, please turn on the water valve to let the water go 

out. 

Regulator installation

       

                 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure adjustment knob 

Connecting shelf 

Copper air mouth 

Pressure meter 

Air filting bottle 

Air pipe 

Drain knob 

Electromagnetic air-in 

Air in   

10 

Air out 

11 

Pressure meter face 

Summary of Contents for LGK 100IJ

Page 1: ...3 LGK 100IJ CUTTING MACHINE USER MANUAL...

Page 2: ...rt or property lose if it is not followed The words after this sign means there is potential risk which may cause equipment fault or break if it is not followed Version Version YF TAE 0099 A0 Released...

Page 3: ...L PARAMETERS TABLE 12 PANELFUNCTION INSTRUCTION 13 INSTALLATION INSTRUCTION 14 INSTALLATION INSTRUCTION 15 NOTES OR PREVENTIVE MEASURES 16 QUESTIONS TO BE RUN INTO DURING CUTTING 17 MAINTENANCE 18 NOT...

Page 4: ...cause choke Spark and hot workpiece after cutting may cause fire Bad connected cable may cause fire Incompletion connection of workpiece side circuit may cause fire Never cut on the case of tinder st...

Page 5: ...s below to avoid electric shock Keep away from any electric parts Earth the machine and workpiece by professional personnel Cut off the power before installation or checking and restart 5 minutes late...

Page 6: ...en operating on trunks boilers cabins etc Please accept the supervisor s inspection when operating in narrow space Air the room and wear breathe preventive facilities Never operate in degrease washing...

Page 7: ...checking the wire feeding is normal or not or the shooting wire may stab your eyes and face Keep your eyes face or other naked parts away from the end of torch when feeding the wire manually or pressi...

Page 8: ...cemaker or audiphone f Equipments for adjustment and measurement g Anti disturb capability of other used equipments Users should ensure these equipments and the environment are compatible which may ne...

Page 9: ...rm strong plasma arc It has the functions of arc initiation current arc stop current cutting current basic value current current ascending time current descending time gas delay time continuous adjust...

Page 10: ...Hz 50 60 Rate input current A 23 1 21 1 19 9 No load voltage V 276 301 319 Current Range A 23 100 Rate output voltage V 89 2 120 Duty cycle 60 Efficiency 85 No load loss W 80 Power factor 0 93 Insula...

Page 11: ...er heat abnormal indicator 3 over current Abnormal indicator 4 Current adjustment knob 5 Positive output terminal 6 Pilot arc output terminal 7 Torch switch socket 8 Gas electricity system output The...

Page 12: ...e joint with hoop or other ways in case of gas leaking Dry gas with suitable pressure and flow should be supplied If your air source cannot meet above requirements you should consider using sole compr...

Page 13: ...lve turn up the pressure adjusting knob Turn the pressure to rated value meter inside shows Kgf cm2 and then put down the knob means increasing pressure _ means decreasing pressure 6 Scale of the mete...

Page 14: ...is adequately ventilated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to watch the max duty current Response to the selected du...

Page 15: ...d input cable is too long C Output current is not up to the rated value When power voltage departs from the rated value it will make the output current not matched with rated value when voltage is low...

Page 16: ...If scale and loose are found please give a good polish to them then connect them again tightly 4 Avoid water and steam enter into inter machine if they enter into machine please dry inter machine the...

Page 17: ...ontrol wire of gun broken or switch broken 3 Control circuit is broken Contact factory Abnormal indicator is lit meter is normal fan is normal 1 High pressure device is broken 2 IGBT is broken 3 Recti...

Reviews: