Periodic Controls :
For efficient use, preventing the possible failures and optimum life of the boiler periodic controls are important.It is
recommended that periodical controls for the boiler must be made by once in every three months.These periodical
controls are made by authorized technicians by applying following processes.
Burning control (with eye).
Working and safety controls of hydraulic system and the boiler.
Boilers combustion chamber and smoke channels check and cleaning if needed.
Leakage controls of water input - water output of the boiler and flue connections.
Valves check
Pumps check
Yearly Controls :
Yearly controls of the boiler must be made by authorized technicians before the season starts. Flue and flue lines must be
cleaned before calling technicians for yearly controls. In yearly controls authorized technicians apply the following
processes.
Water filter test. Cleaning if needed.
Expansion tank controls, cleaning if needed.
Situation of the insulations and the sections and isolation rope controls.
Working pressure test for burning adjustment with the flue gas measurement system if needed.
Leakproof of the connections of the boiler test.
Valves test for proper opening and closing.
Boiler burning room and possible soot layers on smoke channels are checks and cleanings.
Boiler cleaning
Wh
th
b il
i
d
t
d fi
h
l t
th b il
ll
i l
h
t
h
ib
Sensor of the pressure tests.Cleaning or renewing if needed .
Working and safety controls of hydraulic system and the boiler.
Expansion tank controls, cleaning if needed.
When the boiler is used, soot and fine ash accumulates on the boiler walls, mainly on heat exchanger ribs
and in the flue neck, which reduces heat transfer and the boiler output. The actual quantity of soot and fine
ash will depend on the quality of the fuel used and on the boiler operating conditions.
If the boiler is oversized or was for some reason run at low temperatures, more soot is generated. This may
also result in inadequate chimney thrust.
The boiler must be cleaned regularly, at least once a month, which is done with a steel brush through an
open boiler door.
p
All boiler walls inside the combustion chamber and combustion gases routes should be cleaned.
If a larger quantity of tar has accumulated on internal walls of the combustion chamber, it must be
removed with a scraper or burnt with hard wood ( or coke ), running the boiler at maximum operating
temperature.
Please note
Ashes should be stored ( by using proper glove ) in a noncombustible container properly and transported
outdoors. Other waste must not be stored in this container.
15
Summary of Contents for S.MAX Series
Page 1: ...S MAX SERIES SOLID FUEL BOILER S MAX SERIES SOLID FUEL BOILER 0 S MAX REV 01 2010 0036 0036...
Page 4: ...Boiler dimensions Boiler packaging dimensions 3...
Page 5: ...Technical parameters 4...
Page 17: ...fig 12 fig 13 fig 14 fig 15 16...
Page 22: ...SMAX boiler parts fi 18 fig 18 fig 19 21...
Page 23: ...Spare parts list p p fig 20 22...