user   is   advised   to   read,   defines   an   EN12941   TH2P   R   SL  device   as   offering   an  Assigned

Protection Factor of 20.

The CR-2B01/2013 can only provide this level of protection when used with filters provided by 
the manufacturer marked “ CR-2B01/2013 ” and “EN12941:1998 TH2P R SL”.
The CR-2B01/2013  is certified with the GT-2B01/2013 helmets which is certified to EN 175 B.
The CR-2B01/2013 is manufactured under ISO 9001:2000 Quality System.

                                                                Welding helmet
                                                                 GT-2B01/2013

3. Preconditions for use:
This   Respirator   must   be   used   strictly   in   accordance   with   this   instruction   leaflet   and   the
instructions supplied with the corresponding head-units (hoods).

The user must read and understand all the following "Instructions for Use" well to be able to use
the respiratory protective system correctly.

When the blower unit is switched off little or no respiratory protection is to be expected. When 
the blower unit is switched off a rapid build up of carbon dioxide and depletion of oxygen within 
the head unit may occur and so it is essential not to use the blower unit when it is switched
off.

THE UNIT MUST NOT BE USED:

In an atmosphere that is immediately hazardous to user hygiene or health and
or has oxygen content of less than 17% or contains unknown substances.

In confined spaces or unventilated areas such as tanks, pipes, canals etc.

Near to flames and or sparks 

In areas with danger of explosion.

In an area where there are high winds.

If the blower unit stops working due to any reason, the user must leave the contaminated
area immediately.

If no filter is installed.

It is also essential that:

Nothing is allowed to touch the moving parts.

There is no attempt to modify or alter the unit or filter in any way

Water or other liquids enter the unit in any way – in particular the motor and fan, the filter
or the battery.

Summary of Contents for CR-2B01/2013

Page 1: ...CR 2B01 2013 Powered Air Purifying Respirator Item number 605813 User Instruction Manual 2 2...

Page 2: ...his leaflet Contents 1 Introduction 2 Approvals 3 Preconditions for use 4 System Overview 5 Unpacking Assembly Usage 6 Before Use 7 Maintenance Cleaning 8 Fault finding 9 Storage and transportation 10...

Page 3: ...switched off little or no respiratory protection is to be expected When the blower unit is switched off a rapid build up of carbon dioxide and depletion of oxygen within the head unit may occur and s...

Page 4: ...unit and seek medical advice 4 System Overview The CR 2B01 2013 unit is a belt mounted powered respirator with a replaceable disposable high efficiency particle filter system The system is certified w...

Page 5: ...6 User Instructions 5 2 Assembly Attach the respiratory unit onto the belt Pass the inner strap through the back of the blower loops The pass through the 3 belt loops and then through the buckle Fit...

Page 6: ...Pre Filter As soon as the warning alarm sounds the pre filter should be exchanged or checked In very dusty area s this can be necessary on a frequent basis The filters must be regularly checked see Ai...

Page 7: ...ilter The pre filter is a sleeve which is fitted over the main filter To remove replace simply pull off the old filter and stretch the new one into position It s important to ensure that the filter me...

Page 8: ...5 3 Usage Switch on the unit by pressing the ON OFF button on the control panel The airflow can be either the low speed 180 l min or the high speed 220 l min The speed denoted buy the lit LED and the...

Page 9: ...r additional suggestions 6 Before use 6 1 Inspection before use Each time before starting work check that all components are in good condition with no visible damage like holes tears etc Replace any d...

Page 10: ...regime and keeps the battery fully charged The charging time is 6 to 8 hours 6 3 1 Battery charging 1 Check that the voltage of the electrical power supply is correct 2 Plug the charger into the sock...

Page 11: ...the CR 2B01 2013 system it is necessary to check the following That all parts of the air supply system are assembled properly The battery and its connector Whether the charger is not faulty or malfun...

Page 12: ...s items Do not store outside the temperature range of 0 C to 40 C or with humidity above 75 RH 10 List of Parts and Assembly Drawing ITEM NUMBER DESCRIPTION PART NUMBER 1 Face seal for GT 2B01 2013 60...

Page 13: ...rate below 170L min Actual Protection Factor APF 20 Noise level 65dBA Operating time greater than 8 hours on minimum flow rate with a new filter and fully charged battery in a clean environment 5 hou...

Page 14: ...This guarantee is subject to The CR 2B01 2013 unit has been used solely for the purpose for which it is intended The CR 2B01 2013 unit has not been subject to misuse accident modification or repair N...

Reviews: