Make   sure   that   the   headpiece   fits   the   user's   face   perfectly.   Only   then   the   efficiency   of   the
system is sufficient. The protective factor of the complete system is reduced if the seal of the
headpiece is not fitted properly, for eg. Due to beards or long hair intervening into the seal line. 
There is a possibility that the hose to the head unit may become caught up in use. The blower
unit should be positioned on the person in such a way as to reduce this possibility.
Filters cannot be fitted directly to the head units and should not be adapted to do so. Correct
respiratory protection will not be provided if any parts of the equipment are modified.
At very high work rates the pressure in the device may become negative at peak inhalation flow.
CR-2B01/2013 systems are for use only by competent, trained personnel.
Filters should not be modified to fit different blower units.

ATTENTION!   If   any   of   these   conditions   is   not   kept   or   followed,   the   warranty   is
automatically invalid.

The user is advised to leave the contaminated area immediately if:

The Manufacturer’s Minimum Design Flow (MMDF) warning Alarm sounds.
Breathing becomes difficult.
Dizziness or distress occurs.
Any part of the system becomes damaged.
Airflow into the Head-Unit decreases or stops.
Contaminant can be smelt or tasted inside the Head-Unit
Materials   that   may   come   into   contact   with   the   users   skin   are   not   known   to   cause   allergic
reactions to the majority of individuals but in the unlikely event of a reaction, the user should
immediately leave the contaminated area, remove the unit and seek medical advice.

4. System Overview:
The  CR-2B01/2013  unit is a belt mounted powered respirator with a replaceable, disposable
high  efficiency particle filter  system. The system is certified with the  PL-2B01/2013 and  GT-
2B01/2013 helmets and the helmet covers head sizes from 535 to 600mm circumference.
The CR-2B01/2013 unit contains a removable 8hr rechargeable battery pack.
The CR-2B01/2013 unit will warn the user when the MMDF of 170 L/min, is not achieved with its
audible alarm. 
In operation once the alarm sounds, the user must immediately leave the work area and reach
an area nominated to be safe. The unit has audible and visual alarms for a low battery and a
blocked  filter. Depending on the fault, the user should replace the Pre Filter with a new one (In
very   dusty   environments   the   Pre   Filter   will   need   changing   frequently)   and   or   re-charge   or
change the battery for a fully charged one. If the blocked filter alarm continues to sound the
main filter should be changes. Only when the unit will function with the alarm switched off and
the flow rate has been tested to be acceptable, should the user return to the work place.
The filter has been developed especially for this unit. It is used to  filter the air the user will
breathe. It is essential that the user checks the filter for any signs of damage or deformation that
could potentially let contaminated air into the unit. The filter must be disposed of if the filter is
damaged or if clogged to the point of triggering the systems alarm mechanism.
The removable rechargeable battery used is a Lithium Iron cell. When supplied the battery may
hold a small charge, the unit should be run flat and then charged for sixteen hours before the
first use.

5. Unpacking / Assembly / Usage:

Summary of Contents for CR-2B01/2013

Page 1: ...CR 2B01 2013 Powered Air Purifying Respirator Item number 605813 User Instruction Manual 2 2...

Page 2: ...his leaflet Contents 1 Introduction 2 Approvals 3 Preconditions for use 4 System Overview 5 Unpacking Assembly Usage 6 Before Use 7 Maintenance Cleaning 8 Fault finding 9 Storage and transportation 10...

Page 3: ...switched off little or no respiratory protection is to be expected When the blower unit is switched off a rapid build up of carbon dioxide and depletion of oxygen within the head unit may occur and s...

Page 4: ...unit and seek medical advice 4 System Overview The CR 2B01 2013 unit is a belt mounted powered respirator with a replaceable disposable high efficiency particle filter system The system is certified w...

Page 5: ...6 User Instructions 5 2 Assembly Attach the respiratory unit onto the belt Pass the inner strap through the back of the blower loops The pass through the 3 belt loops and then through the buckle Fit...

Page 6: ...Pre Filter As soon as the warning alarm sounds the pre filter should be exchanged or checked In very dusty area s this can be necessary on a frequent basis The filters must be regularly checked see Ai...

Page 7: ...ilter The pre filter is a sleeve which is fitted over the main filter To remove replace simply pull off the old filter and stretch the new one into position It s important to ensure that the filter me...

Page 8: ...5 3 Usage Switch on the unit by pressing the ON OFF button on the control panel The airflow can be either the low speed 180 l min or the high speed 220 l min The speed denoted buy the lit LED and the...

Page 9: ...r additional suggestions 6 Before use 6 1 Inspection before use Each time before starting work check that all components are in good condition with no visible damage like holes tears etc Replace any d...

Page 10: ...regime and keeps the battery fully charged The charging time is 6 to 8 hours 6 3 1 Battery charging 1 Check that the voltage of the electrical power supply is correct 2 Plug the charger into the sock...

Page 11: ...the CR 2B01 2013 system it is necessary to check the following That all parts of the air supply system are assembled properly The battery and its connector Whether the charger is not faulty or malfun...

Page 12: ...s items Do not store outside the temperature range of 0 C to 40 C or with humidity above 75 RH 10 List of Parts and Assembly Drawing ITEM NUMBER DESCRIPTION PART NUMBER 1 Face seal for GT 2B01 2013 60...

Page 13: ...rate below 170L min Actual Protection Factor APF 20 Noise level 65dBA Operating time greater than 8 hours on minimum flow rate with a new filter and fully charged battery in a clean environment 5 hou...