Rimage Professional™ 3400 and 5400N Diagnostic Tests
2001497_A
9
Lift Motion Detector (LM)
The lift motion detector senses when the lift arm is in motion.
When the lift arm is in motion, the operator panel
displays a digital value, signified by ‘X’.
Note:
These digital values change continuously
while the carousel is in motion.
Carousel Motion Detector (CM)
The carousel motion detector senses when the carousel is in motion.
When the carousel is in motion, the operator panel
displays a digital value, signified by ‘X’.
Note:
These digital values change continuously
while the lift arm is in motion.
Door Sensor (D)
The door sensor is located on the right side of the control panel on the front of the autoloader. It detects
when the front door is open and closed.
1.
Close the
front door
. The operator panel
displays:
2.
Open the
front door
. The operator panel
displays:
Gripper Plunger Sensor (G)
The gripper plunger sensor is located inside the lift arm. It detects when a disc is present on the lift arm.
1.
Place a
disc
on the lift arm. The operator panel
displays:
2.
Remove the
disc
from the lift arm. The
operator panel displays:
X X
X X
1
1 1 1 1
L M C M
D
G O L C
X X
X X
0
1 1 1 1
L M C M
D
G O L C
X X
X X
0
0
1 1 1
L M C M
D
G
O L C
X X
X X
0
1
1 1 1
L M C M
D
G
O L C
X X
X X
0 1 1 1 1
L M
C M
D G O L C
X X
X X
0 1 1 1 1
L M
C M
D G O L C