background image

Rimage Professional™ 3400 and 5400N Diagnostic Tests  

 

2001497_A

 

Cycle 4: Cycle Discs at the Carousel 

1.

 

Select diagnostic test 2. Refer to page 3. 

2.

 

Make sure the printer tray and recorder trays are closed. 

3.

 

Place 

discs

 (Qty. 50) in carousel bin 1. 

 

Important! 

Make sure that carousel bins 2 and 3 are empty. 

4.

 

Press 

button 1 

to begin the cycle. The operator panel displays 

[02 CYCLE TEST CHECKING DEVICES]

.  

 

The autoloader checks all the carousel bins for discs. 

 

The lift arm picks discs from bin 1 and places them in the output bin. This cycle continues until the 
output bin is full. 

 

Note:

 The output bin holds 8 discs. 

 

When the output bin is full, the lift arm begins to cycle the discs around the carousel, placing discs in 
a bin until it is full. 

 

The operator panel displays 

[02 CYCLE TEST CYCLE = XXXXXX]

, where X is the number of cycles 

completed. 

5.

 

Press 

button 1

 to stop the cycle and return to diagnostic test mode. The operator panel displays 

[00 

CHOOSE DIAGNOSTIC]

6.

 

Remove the 

discs 

from the carousel and the output bin. 

Cycle 5: Cycle Discs between the Carousel and the Printer 

1.

 

Select diagnostic test 2. Refer to page 3. 

2.

 

Select 

diagnostic test 2

. The operator panel displays 

[02 CYCLE TEST SETUP DEVICES]

3.

 

Press 

button 2 

to open the printer tray. 

 

Important! 

Make sure that both recorder trays are closed. 

4.

 

Place 

discs

 (Qty. 50) in carousel bin 1. 

 

Important! 

Make sure that bins 2 and 3 are empty. 

5.

 

Press 

button 1 

to begin the cycle. The operator panel displays 

[02 CYCLE TEST CHECKING DEVICES]

 

The autoloader checks all the carousel bins for discs. 

 

The lift arm picks a disc from bin 1, places it on the printer tray, and then places the disc in the output 
bin. This cycle continues until the output bin is full. 

 

Note:

 The output bin holds 8 discs. 

 

When the output bin is full, the lift arm begins to cycle the discs from the printer to the carousel, 
placing discs in a bin until it is full. 

 

The operator panel displays 

[02 CYCLE TEST CYCLE = XXXXXX]

, where X is the number of cycles 

completed.  

7.

 

Press 

button 1

 to stop the cycle and return to diagnostic test mode. 

8.

 

Remove the 

discs 

from the printer tray, output bin, and carousel. 

Summary of Contents for Professional 3400

Page 1: ...Rimage Professional 3400 and 5400N Diagnostic Tests...

Page 2: ...a Disc at the Recorder 4 Cycle 3 Cycle a Disc between the Recorder and the Printer 4 Cycle 4 Cycle Discs at the Carousel 5 Cycle 5 Cycle Discs between the Carousel and the Printer 5 Cycle 6 Cycle the...

Page 3: ...GNOSTIC displays on the operator panel Note Other status messages display on the operator panel while button 1 is being held in Do not release the button until the operator panel displays 00 CHOOSE DI...

Page 4: ...s Test 1 Solenoid Test Diagnostic This test cycles the solenoid in the lift arm 1 Make sure the autoloader is in diagnostic test mode Refer to the Access and Select Diagnostic Tests section on page 1...

Page 5: ...the devices are set up for a cycle press and hold button 1 to display an option menu on the operator panel Each option displays for 3 seconds Release button 1 while an option is displayed to select th...

Page 6: ...e recorder tray 8 Repeat steps 1 7 for the second recorder tray Cycle 3 Cycle a Disc between the Recorder and the Printer 1 Select diagnostic test 2 Refer to page 3 2 Press button 2 to open the printe...

Page 7: ...IC 6 Remove the discs from the carousel and the output bin Cycle 5 Cycle Discs between the Carousel and the Printer 1 Select diagnostic test 2 Refer to page 3 2 Select diagnostic test 2 The operator p...

Page 8: ...te When diagnostic test 3 is complete the autoloader automatically exits the test and returns to diagnostic test mode 1 Make sure the autoloader is in diagnostic test mode Refer to the Access and Sele...

Page 9: ...he autoloader automatically begins to take the following measurements Carousel bin top measurement The autoloader measures the distance between the top of the lift column and the top edge of the carou...

Page 10: ...s the status of the motion detectors and sensors during each test X X Indicates the various digital values for the lift motion and carousel motion detectors Note These digital values change continuous...

Page 11: ...e lift arm is in motion Door Sensor D The door sensor is located on the right side of the control panel on the front of the autoloader It detects when the front door is open and closed 1 Close the fro...

Page 12: ...ually move the lift arm away from the top of the lift column The operator panel displays 2 Move the lift arm to the top of the lift column The operator panel displays Carousel Home Sensor C The carous...

Page 13: ...XX CYCLE XXXXX Tip INDEX XXXXX is the top lift arm speed CYCLE XXXXX is the number of cycles completed 3 Release button 1 The test starts automatically The lift arm moves in and out of carousel bin 1...

Page 14: ...unctional and technical description of the problem Exact error message received Contact Rimage Europe Rimage Corporation reserves the right to make improvements to the equipment and software described...