Diagnostic Tests for the Rimage Professional™ 3400 and 5400N
6
2001497_A
Cycle 6: Cycle the Lift Arm
1.
Select diagnostic test 2. Refer to page 3.
2.
Make sure that the printer tray and recorder trays are closed.
3.
Make sure that carousel bins 1, 2, and 3 are empty.
4.
Press
button 1
to begin the cycle. The operator panel displays
[02 CYCLE TEST CHECKING DEVICES]
.
•
The autoloader checks all the carousel bins for discs.
•
The lift arm moves in and out of each carousel bin.
•
The operator panel displays
[02 CYCLE TEST CYCLE = XXXXXX]
, where X is the number of cycles
completed.
5.
Press
button 1
to stop the cycle and return to diagnostic test mode. The operator panel displays
[00
CHOOSE DIAGNOSTIC]
.
Test 3 – Calibration Test Diagnostic
This test calibrates the lift arm and carousel.
Note:
When diagnostic test 3 is complete, the autoloader automatically exits the test and returns to
diagnostic test mode.
1.
Make sure the autoloader is in diagnostic test mode. Refer to the
Access and Select Diagnostic Tests
section on page 1.
2.
Remove all media from the autoloader. Make sure the printer tray, recorder trays, carousel, and output
bin are free of discs.
3.
Press
button 1
three times and hold it until the operator panel displays
[03 EMPTY CAROUSEL DISC ON
GRIPPER]
. The indicator light on button 1 flashes and the system pauses.
4.
Place one
disc
on the lift arm.
Tip:
Press the disc into the gripper while pressing the disc release button on top of the lift arm.
5.
Press
button 1
.
•
The lift arm moves into position above carousel bin 1.
•
The indicator lights on buttons 1 and 2 flash.
•
The operator panel displays
[03 CAL CAR POS 00000]
.
Tip: 00000
is the default carousel position when the lift arm is positioned at carousel
bin 1.
•
The autoloader pauses.