14
5.3.2 Connection of the protective earth conductor
The RDG generator must never be operated without
a PE conductor connected. In addition, a PE con-
ductor with a minimum cross-section of 2.5 mm²
must be connected from the RDG generator to every
ultrasonic converter.
5.3.3 Equipotential bonding
All components of an ultrasonic system must be con-
nected to one main potential. This connection can be
established e.g. via a mounting plate or a cable with a
minimum cross-section of 6 mm².
5.4 EMC compliant installation
RINCO ULTRASONICS AG has performed
conformity tests with the RDG-type generators
on specific, defined vibration units. Ultrasonic
systems which have been assessed
in this way are referred to as "CE-typical ultrasonic
systems" in the following.
5.4.1 Installation of a CE-typical ultrasonic system
The following points must be observed in order to
ensure that the connections are compliant with EMC
requirements:
• Apply ferrite on both sides to HF cables.
• Data cables must not be routed parallel to the HF cable
or to the mains cable.
• Use cables which are shielded on both sides.