Generator
Current power output in W
Current power output in %
Voltage at
POWER_AOUT in V
RDG20-2000 1600
80
6.67
RDG30-1000 1000
100
8.33
RDG35-900
360
40
3.33
RDG40-800
400
50
4.17
RDG70-100
30
30
2.50
US_ACTIVE_OUT
If ultrasonic operation is activated, this is signalled
with 24VDC at this output.
SSW1_PRESS_IN.1
No function
POWER_AOUT
This analogue output outputs a linear voltage from 0 to
10VDC which is proportional to the current power. The
maximum output voltage of 10VDC is used for 120% of
the rated generator output power.
Example: POWER_AOUT (0 - 10 V)
ERROR_24_VDC_IN / ERROR_OUT
Normally, ERROR_24VDC_IN and ERROR_OUT are
short-circuited via relay contacts. If a fault is present
this connection is interrupted.
A maximum of 24V / 0.5A can be applied to this output.
HOMEPOS_24VDC_IN / HOMEPOS_OUT
If the input HOMEPOSITION_IN is connected to 24VDC
then HOMEPOS_24VDC_IN and HOMEPOSITION_
OUT are short-circuited via relay contacts.
READY_OUT
If the RDG generator is ready for the next weld, then
this is signalled with 24VDC at this output. If the output
is connected to 0VDC then the generator is switched
off, in the process of welding or blocked by a fault.
READY_1_OUT
If the RDG generator is ready for the next weld and
the input HOMEPOSITION_IN (STO_3) is connected
to 24VDC then this is signalled with a 24VDC signal
at this output.
GND
Reference ground for 24VDC_OUT.