19.4 Limit error LED3
Error
Cause
Response
Error remedy
Maximum power
- Power too high
- Error message is generated
- With this type of error,
exceeded
- Ultrasonic process is
it is also vital to
aborted
reconsider the choice of
- A new ultrasonic process is
delay time
started at the last
- Check the workpiece
welding frequency
- Check the process
sequence
- Check/replace the
oscillator system
Analogue amplitude - The voltage at the external - Error message is generated
- Correct the voltage at the
too low
analogue amplitude-
- Ultrasonic process is
external analogue
input is below the
aborted
amplitude input
value for the start
- A new ultrasonic process is
amplitude (less than
started at the last
3V) before or during
welding frequency
the ultrasonic process.
- Start of the ultrasonic process
is refused