background image

DIGITAL DIMMING THERMOSTAT DAY & NIGHT + TIMER 

 

DTC-120 

  User Manual 

 
Instructions:     

 
DTC-120  is  one  of  latest  developed  dimming  thermostat  series  products  which  are  applied  to  aquatic 
and reptile market. Practicality functions, elegant appearance. 
 
One channel is for temperature PID heating, one channel for timer controlling. 
 
We adopt PID techniques, a very accurate temperature control mode, DTC-120 operates by reducing the 
current  (amps)  to  the  heating  device  which  in  turn  reduces  the  amount  of  electricity  it  uses  and  the 
amount of heat it produces, The DTC-120 uses its intelligence to determine how much current to supply, 
when the sensor reading starts to get closer to the target temperature it will reduce the current so that 
the area will not over heat once the target has been reached. Also if the temperature starts to fall, the 
DTC-120  will  start  to  send  power  to  your  heating  devices  to  prevent  the  temperature  dropping  below 
the target temperature. 
 
Compared to ON/OFF control mode, DTC-120 can avoid the unstable change of temperature and lighting 
caused by switching on & off frequently, so  DTC-120 is more conducive  to the health of reptiles,  even 
DTC-120 can make the heater or other electrical equipment maintain long service life, and save money 
for users. 

 
Main features:     

1.

 

Big LCD display, friendly interface, easy to read, operates and set the parameters. 

2.

 

Using real-time clock to control the light, simulating the day and night as real environment. 

3.

 

Small and elegant appearance, can adopt attached on the glass, or stand on the table, or install 
into the aquarium and terrarium, fit for different operating requirements of users. 

 
Main Functions and Parameters:     
 

Temperature controlling range: 0~50

                       

Temperature measuring range: 0~50

 

Resolution: 0.1

; Accuracy: 

±

1.0

                         

Input: 1 NTC sensor 

Time unit: hour (24:00 format)                                     

Product consumption: 

3W 

Input voltage: 220Vac

±

15%(standard)/50HZ       

Ambient Requirements: Temperature: -10~60

;Humidity: 20%~85%

 

Timer output: resistive load MAX 1100W; inductive load MAX 275W; incandescent bulb MAX 220W 

Heating output: resistive load MAX 440W 

 

Icons: 

    : Icon flashing: Heating output;                 

  : Icon flashing: The timer is on; 

    : Upper part rapid flashing: Alarm status over temperature 

  :

 

Icon flashing: Daytime;                           

  :

 

Icon flashing: Nighttime 

Menu instructions: 

Menu item 

Set 

Default value 

Remark 

HEAT

MODE

 

HEAT 

HEAT 

 

Daytime Temperature

SET

 

0.0~50.0

 

25

 

Set step 0.1

 

Nighttime Temperature

SET

    0.0~50.0

 

20

 

 

Daytime FROM 

 

00:00—22:59  08:00 

 

Daytime TO 

 

01:00—23:59  18:00 

If TO time is earlier than FROM 

time, display error message "ERR". 

Alarm over temperature 

 

0.0~5.0

 

5.0

 

Set step 0.1

 

First Timing control L1: 

ON: FROM, OFF: TO 

00:00~23:59 

00:00~06:00 

Disabled if FROM and TO are same 

Second Timing control L2: 

ON: FROM, OFF: TO 

00:00~23:59 

12:00~18:00 

Disabled if FROM and TO are same 

Real Time     

00:00~23:59 

Real-time 

 

 
Parameters setting:     

Parameters would be set according to the following circular mode in the first time. All the parameters 
are set and saved instantly. 
First of all, make sure the power is on. 

1.

 

Daytime temperature setting: 

Press SET key for 3 seconds to display the default temperature value while icon SET and 

  flashing, 

then press UP or DOWN key to select the ideal temperature you want. 

2.

 

Nighttime temperature setting: 

Press SET key once to display the default temperature value while icon SET and 

  flashing, then 

press UP or DOWN key to select the ideal temperature you want. 

3.

 

Over temperature alarm setting:   

Press SET key once until lower part of icon 

  flashing and display the current over temperature 

alarm value, press UP or DOWN key to select the idea over temperature you want. 

4.

 

Timing setting: 

Notice that while start time and end time is same, this timing control become invalid 
4.1. First timing control L1: 
A. Start time setting: Press SET key until display L1 and FROM icon flashing, at the same time display the 
default time, press UP or DOWN key to set the hour; 
After hour set, press SET key to set the minute, press UP or DOWN key to set the value; 
B. End time setting: When start time is already finished, press SET key and then TO icon flashing, you 
can set end time in the same method. 
4.2 Second timing control L2: The same operation with first timing control L1. 

5.

 

Real-time setting: 

Press SET key, icon 

  flashing and display current hour set value, press UP or DOWN key to adjust 

Reviews: