SET

RST

SET

SET

SET

SET

SET

SET

RST

3

.

2

 

Set

 

the stop temperature

Press  

SET

 

key

 

can

 

set

 

the stop temperature

press

       

key

 

can

 

adjust the stop temperature; when finishing 

adjustment, 
press

 

RST

 key to save and exit, or auto save  and exit after 15 

seconds without any operation.

Normal working status

Single-press

Adjust

Single-press or 
no operation 15 sec.

Normal working status

3.2 Set

 

Other Parameters

 

Press  

  key for 3 seconds, enter into menu setting mode. 

Press            ,           key can shift parameter. If need to change 
the value of the parameter, press 

SET

 key, then use            key 

to adjust the parameters’s value. When finishing setting, press 

 key to return to menu.Adjust the parameters in turn. When 

finishing all settings, press  

  key 3 seconds or no 

operation for 15 seconds to save and exit.

SET

SET

RST

Normal working status

Press on
3 sec.

Show low temp limit

Shift menu

Single-press

Set low temp limit

Adjust

Show high temp limit

Shift menu

Single-press

Single-press

Set high temp limit

Adjust

Shift menu

Single-press

Single-press

Calibration

Set calibration

Adjust

Single-press or 
no operation 15 sec.

Normal working status

Alarm, Error & Toubleshooting

Code

Reason

Troubleshooting

EEH

Sensor short circuit

or exceed the

highest measuring

temperature

Check the temperature of environment

where the sensor is placed, and whether

the sensor is short circuit, then repair

correspondingly.

EEL

Sensor open circuit

or exceed the

lowest measuring

temperature

Check the temperature of environment

where the sensor is placed, and whether

the sensor is open circuit, then repair

correspondingly.

Alarm error and troubleshooting

When alarm occur

,      

icon

 

flash, and

 

buzzer

 

sounds, if

 

it

 

is

 

not 

sensor fault, the

 

fault

 

code and temperature value will alternate 

display, e.g. If it show FS, means the room sensor temp exceed 
the storage protection temp in the defrost mode; if it is sensor 
fault, it will only display the fault code. 

Attention

When

 

alarming, press

 

any

 

key

 

to

 

mute the alarm, but the icon

   

will keep flashing, and

 

the

 

fault

 

code

 

will

 

keep displaying  until 

trouble removal.

Accessory

Sensor wire x

 

1

;

 

slide fastener 

tailgate 

x

 

2

x

 

1

user

 

manual

 

x

 

1; 

4.1 Sensor 

The sensors that meet RINGDER criteria can apply to the 

product, and the sensor cannot be put into the water directly. 

The below is some parameters:

Wire: 

; sensor size: 

φ2.1

mm*2m

φ4

mm*2

0

mm

The

 

controller

 

can

 

be

 

installed

 

as

 

far

 

as about

 1

00m

but

 

the

 

cross section of the shielded wire must above 1mm 

and any head of the wire  mustn’t connect earth.

Attention please:

This

 

model

 

controller

 

adopts

 

NTC sensor without positive 

and negative polarity, so no requirement for connection 
order.

Please

 

choose

 

the

 

suitable wire rod to connect, and check 

connection fastness.

Please

 

remember to cut off the power supply before 

connecting.

This product has passed the European CE certification, 