Maintenance/Repair
29/56
Pos : 12.30. 1 / 9 Wart ung/ Ins tandsetzung/RI /Übersc hrift: Aus bau der Abs augt urbi ne @ 0\ mod_1269597671546_131. doc x @ 3779 @ 2 @ 1
9.5
Disassembly of the suction turbine
Pos : 12.30. 2 / 1 Grundlegende Sic her hei tshi nweise/ Signal wort-F eld " War nung" @ 0\ mod_1261404807286_131. doc x @ 893 @ @ 1
WARNING
Pos : 12.30. 3 / 9 Wart ung/ Ins tandsetzung/ Warnt ext El ektr of achkr af t @ 0 \ mod_1264055838943_131.doc x @ 1680 @ @ 1
•
These works may only be carried out by an electrician.
Pos : 12.30. 4 / 9 Wart ung/ Ins tandsetzung/ Arbeiten an der T urbi ne O berfläc hentemper at ur @ 6 \ mod_1401954130950_131.doc x @ 60471 @ @ 1
• Before any work near or at the extraction turbine, let its surface cool down to below 50°C or wear
safety gloves and work protection clothing that isolate against the arising temperatures.
Pos : 12.30. 5 / 1 Grundlegende Sic her hei tshi nweise/ Hinweis N etzs tec ker zi ehen @ 0\ mod_1261407392098_131.doc x @ 939 @ @ 1
Before starting work
remove the plug from the wall socket!
Pos : 12.30. 6 / 9 Wart ung/ Ins tandsetzung/R A/Skizze Aus bau Saugt urbi ne (5, 5kW) @ 9\ mod_1428485186205_0.doc x @ 90044 @ @ 1
Pos : 12.30. 7 / 9 Wart ung/ Ins tandsetzung/R A/Skizze Aus bau Saugt urbi ne (3kW) @ 4\ mod_1359375264465_0.doc x @ 38165 @ @ 1
Pos : 12.30. 8 / 9 Wart ung/ Ins tandsetzung/R A/Aus bau der T urbine R A-G eräte @ 1\ mod_1336487925596_131. doc x @ 12739 @ @ 1
•
Loosen screw connection of the front cover (1), remove front cover (2).
•
Disconnect motor connection cable (3), loosen screw connection at the back (4) and remove back.
(5)
•
Loosen hose clamps of the hose attachment at the turbine (6), remove hoses (7).
•
ATTENTION: Do not reach into the turbine openings with your hands or other body parts.
There is a danger of injury!
•
Loosen screw connection of the turbine to the basic plate (only at 3 kW and 2x3kW) (8), turbine
may be removed (9).
•
Attachment is performed in the opposite order.