4.

Rotate freewheel slowly for several minutes to break
up and dissolve any oily residue.

5.

Remove plug (B) from 6 o’clock position and drain
mineral spirits. Remove plug (C) for better drainage.

6.

Reinstall and tighten plug (B).

7.

Relubricate the freewheel according to Oil
Lubrication Filling Procedure.

8.

Reinstall and tighten open plugs to prevent leakage.

Grease Lubrication

Use greases selected from the following table:
FISKE BROS.

Lubriplate “Aero”

Lubriplate “Low-Temp”

MOBIL

Mobilith SHC-100

Mobilgrease XHP 221

Note:

FRSG-300 thru 1000 freewheels are shipped from

Ringspann packed with FISKE BROS. Lubricate “Aero”

Do not use lubricants containing EP (extreme
pressure) additives such as sulfur phosphate,
graphite or molybdenum disulfide.

Use no other greases unless a specific
recommendation has been made by Ringspann.

If ambient temperature of freewheel application is
below +20°F/-7°C or above +120°F/ + 55°C, consult
Ringspann for special lubricant recommendations.

Grease lubrication may be used if:

o

The freewheel is inaccessible for frequent
lubrication maintenance.

o

Conditions do not permit maintenance frequency
required for oil lubricated freewheels.

o

The freewheel orientation is vertical (or greater
than 5 degrees from horizontal).

o

The freewheel is operated in the presence of
severe abrasive dust.

Do not attempt to convert oil lubricated freewheels to
grease lubrication. Any such conversion may result
in malfunction and will void any warranty.

Grease Lubrication Maintenance

Add grease to freewheel once per month under normal
operating conditions. Under severe operating conditions,
such as heavy dust or twenty-four hours per day
operation, grease should be added every 2 weeks

Grease Lubrication Procedure

1.

Wipe all grease fittings clean and then pump new
grease into all fittings until clean grease flows out
around the seals on both sides of the freewheel.

2.

Lubrication should be done with the freewheel at
normal operating temperature.

Note:

Freewheels are designed to purge excess grease

during operation. Purge will stop as soon as internal
temperatures and pressures stabilize.

Use Recommended Greases Only

Freewheel Rebuilding Service

Disassembly and repair of Ringspann

freewheels in the field is not recommended and will void
any warranty.

Ringspann freewheels are precision devices
manufactured under careful controls to meet exacting
standards. When reconditioning is required, freewheels
should be returned to Ringspann for service

Rotating Equipment

Rotating equipment is potentially

dangerous and should be properly guarded. The user
should comply with all applicable safety codes to guard
rotating equipment.

Warranty

Ringspann Corporation “seller” agrees to repair or
replace (at its sole option), defective materials or
workmanship for a period of one year from the date of
delivery. Seller must be notified of such a defect within a
reasonable time after discovery (not to exceed thirty (30)
days), and the defective product must be delivered,
prepaid to the seller’s factory with evidence that, it has
been properly installed, maintained and operated in
accordance with the seller’s instructions. Seller’s limited
warranty excludes remedy for damage or defect caused
by abuse; failure to resist corrosion or erosion from any
corrosive agent or fluid, due to deposits of foreign
material from any fluid; modifications not executed by
Seller; improper installation or operation; defects or
failures arising out of, in any way related to, or as a
result either direct or indirect, of the Buyer’s failure to
properly advise Seller of all normal and special operating
conditions, known to or suspected by Buyer, when Seller
is manufacturing the Equipment for a specific operation;
or normal wear and tear under usage. This remedy is
exclusive and is given in lieu of any warranty of
merchantability, fitness, for a particular purpose or any
other warranty, whether express or implied. Seller shall
not be liable for consequential damages (including but
not limited to, loss of use, lost profits, business
interruption and the like), incidental damages, indirect
damages, whether the claim for such damage is based
upon warranty, contract, tort, strict liability or any other
theory of recovery

.

RINGSPANN

Tel: 847-678-3581

CORPORATION

Fax: 847-678-3583

10550 Anderson Place

Web: www.ringspanncorp.com

Franklin Park, IL 60131

Email: info@ringspanncorp.com

Summary of Contents for FRS Series

Page 1: ...e Instructions Ringspann Freewheel Clutches FRS 300 thru 1000 FRZ 300 thru 1000 FRSG 300 thru 1000 RINGSPANN Tel 847 678 3581 CORPORATION Fax 847 678 3583 10550 Anderson Place Web www ringspanncorp com Franklin Park IL 60131 Email info ringspanncorp com ...

Page 2: ...l and key on the shaft Note Oil lubricated freewheels may only be used on applications with mounting orientations within 5 degrees of horizontal Grease lubricated freewheels may be used on applications with non horizontal orientations Apply pressure only to face of freewheel inner ring 2 Application of pressure to the outer ring could damage the bearings For ease of mounting it is permissible for ...

Page 3: ...ckstopping 1 2 full Indexing 7 8 full 3 To assure continued efficiency of operation flush freewheel every 6 months with mineral spirits Do not use any solvent containing Carbon Tetrachloride as seal damage may occur Important Under severe operating conditions such as heavy dust or twenty four hours per day operation flushing may be required at shorter intervals Flushing will remove waxes and gums ...

Page 4: ... pressures stabilize Use Recommended Greases Only Freewheel Rebuilding Service Disassembly and repair of Ringspann freewheels in the field is not recommended and will void any warranty Ringspann freewheels are precision devices manufactured under careful controls to meet exacting standards When reconditioning is required freewheels should be returned to Ringspann for service Rotating Equipment Rot...

Reviews: