Installation and opreating instructios for tor-
sionally stiff gear couplings
RDZ…DTO/…DFO
E 06.705
As of: 12.08.2020
Version: 02
Signed: SCCE
Checked: SCHW
No. of pages: 21 Page: 17
Figure 8.2: Measuring the angular misalignment
9. Start-up and lubrication
9.1 Start-up
Before putting it into operation for the first time, the following parameters need to be
checked:
-
the tightening torque of all screws,
-
the tightness of the set screws,
-
the alignment of the coupling,
-
the clearance L.
The operator has the task of mounting a suitable coupling protection to prevent the unin-
tended touching of the coupling during operation. It may only be removed when the ma-
chine is at a standstill.
During commissioning, attention must be paid to vibrations and running noises. If any vibra-
tions or unusual running noises should occur, the drive unit must be immediately switched
off.
9.2 Lubrication
The initial filling of the coupling with lubricant is described in the following. Only lubricants
that have been approved by RINGSPANN may be used.
Manufac-
turer
Lubricant
CERAN MS
MOBILGREASE XTC
RAVENOL Amber
Getriebefließfett
Manufac-
turer
Lubricant
Mobilux EP 111
GRAFLOSCON C-SG 0
ULTRA,
C-SG 1000 ULTRA
CENTOPLEX GLP 500
Table 9.1 Lubricants approved by RINGSPANN