Installation and opreating instructios for tor-
sionally stiff gear couplings
RDZ…DTO/…DFO
E 06.705
As of: 12.08.2020
Version: 02
Signed: SCCE
Checked: SCHW
No. of pages: 21 Page: 18
Before filling the coupling with lubricant, the quantity must be measured in accordance with
table 9.2. After assembly of the flexible coupling halve, the lubricant should be applied in the
cavity between the hub (item 1) and the flexible coupling halve (item 2). This approach
should be carried out for all flexible coupling halves. Afterwards, seal (item 6) should be in-
serted and the two halves should be screwed together via fitting screws. Excess lubricant
must be completely collected and disposed of in an environmentally friendly manner.
Lubricant quantity
Size
RDZ … DTO (Full Flex)
RDZ … DFO (Flex Rigid)
lbs.
oz.
lbs.
oz.
0010
0.07
1.06
0.03
0.53
0015
0.13
2.11
0.07
1.06
0020
0.38
6.00
0.19
2.99
0025
0.51
8.11
0.25
4.06
0030
0.75
12.00
0.38
6.00
0035
0.99
15.87
0.50
7.94
0040
1.74
27.87
0.87
13.94
0045
2.38
38.10
1.19
19.06
0050
3.51
56.08
1.75
28.05
0055
4.26
68.08
2.13
34.05
0060
7.63
122.05
3.81
61.02
0070
14.00
223.98
7.00
112.00
0080
21.16
338.62
10.58
169.31
0090
29.32
469.14
14.66
234.58
0100
39.14
626.24
19.07
305.12
Table 9.2: Lubricant quantity
Attention!
You may not mix different lubricants. The lubricant must be replaced after 6
months.
To replace the lubricant, we recommend disassembling the flexible coupling halves and thor-
oughly cleaning all parts. The re-filling with lubricant should then subsequently take place as