18
Factory preset default dip switch settings
Bank
SW Description
HD49kWi
A28i
HD49kWe
OFF
ON
OFF
ON
OFF
ON
DipSW1
1
Model and flue setting
OFF: Flue length = long
ON: Flue length = short
Ext
2
Temperature settings
OFF: Fixed temp
ON: Remote controller
3
See ‘Temperature settings’
table below
75 °C 55 °C
75 °C
4
5
6
High altitude
OFF: Level 0 (0-900 m)
ON: Level 1 (901-1800 m)
L0
L0
L0
7
Gas type
OFF: LPG
ON: NG
LPG
NG
LPG
NG
LPG
NG
8
Forced combustion
OFF
DipSW2
1
Model and flue setting
OFF: Flue length = long
ON: Flue length = short
Ext
2
Capacity
OFF: 28 L
ON: 26 L
28 L
28 L
28 L
3
Model and exhaust type
OFF: Internal
ON: External
Int
Int
Ext
4
Capacity
OFF: 28 L
ON: 26 L
28 L
28 L
28 L
5
Model and exhaust type
OFF: Internal
ON: External
Int
Int
Ext
6
High altitude
OFF: Level 0 (0-900 m)
ON: Level 1 (901-1800 m)
L0
L0
L0
7
Gas type
OFF: LPG
ON: NG
LPG
NG
LPG
NG
LPG
NG
8
Autoreset
On
On
On
Temperature settings °C - DipSW1 SW2-5
DipSW 1
SW2 of DipSW1 = Off (fixed temp.)
SW2 of DipSW1= On (with controllers)
SW3 SW4 SW5 No controllers
(fixed temp.)
With controllers
(Max. set temp.)
No controllers
(fixed temp.)
With controllers
(Max. set temp.)
Off
Off
Off
55
55
55
55
On
Off
Off
75
75
55
75
Off
On
Off
65
65
55
65
On
On
Off
60
60
55
60
Off
Off
On 50
50
50
50
On
Off
On 42
42
42
42
Off
On
On 85
75
40
40
On
On
On 85
75
70
85
Summary of Contents for A28i
Page 19: ......