15
Brivis Networker
INDOOR UNIT ELECTRIC BOX
NG-2A
G W R
Electronic Control Module
C Y
TSTAT
TW1 TW2
ZONE /
ADD-ON
ZONE A
ZONE B
M
Fn
A1
A2
Fig. 12 – Wiring Circuit for Brivis StarPro Series Heaters with Brivis ICE Add-On
Using Brivis Networker
StarPro model heaters can be configured for zoning and/or Add-On Refrigerative Air Conditioning. For more information
regarding connection to a StarPro unit please refer to the associated heater installer’s manual.
Your zoning requirements may require a 'Brivis Network 516 module' (Brivis Part No. B023178), please refer to the
associated heater installer’s manual.
Fig. 13 – Wiring Circuit for Brivis Classic Series Heaters with Brivis ICE Add-On
Using Brivis Programmable Thermostat
Note:
For Brivis ICE Add-On connection to a Brivis BX5 StarPro heater, a ‘Brivis Network 516 module’ (Brivis Part
No. B023178) must be fitted.
Note:
For Brivis ICE Add-On connection to a Brivis Classic heater (CC3, 2PWN, or BX3) an additional relay
‘ACC LOOM ADD-ON RELAY CLASSIC’ (Brivis Part No. B063283) must be fitted.
Contact Brivis Technical Support for information on superseded Brivis Heaters.
Relay Wires
PCB Wires
Field Supplied Wires
To Add-On Cooling Unit
For connection refer to the installation manual
accompanying the Add-On cooling unit.
Heater
Control
Board
0
1
3
4
2
7
6
8
W
R
Relay
B063283
240V
Active
Terminal
Block
Brown
Red
Red
HEATER
Programmable
Thermostat
R
Y
G W
White
Fan speed terminal block
C
om
m
on (
B)
Lo
w (
R)
M
edi
um
(W
)
H
igh
(B
r)
Blue
*
For Brivis Classic 2PWN units the ‘
Fan speed terminal block
’ is inside the fan housing. The RED wire from the heater PCB
extends to the ‘
Fan speed terminal block
’ with a BROWN wire quick connect fitting. This BROWN wire shall be joined to the
RED wire supplied with ADD-ON relay, i.e. terminal 4.
*