10
Canadian Air Handler Installation and Operation
CAH050E
CAH050CE
Appliance Type
Hydronic Air Handler
(Without Accessory Circulation
Pump)
Hydronic Air Handler
(With Accessory Circulation
Pump)
Installation
Indoor
Suitable for Potable Water Systems
Yes
Configurations
Multi
-
position
Circulation Pump Included
No, Accessory
Yes (to be field installed)
Product Weight
-
lb. (kg) (approximate)
100 (45.5), Shipped 120 (54.5)
105 (47.6), Shipped: 125 (56.7)
Construction
Cabinet: 22 Gauge powder coated steel
Inner panels: 22 Gauge galvanized steel
Insulation:
1/2”
inside blower compartment and door
Nominal CFM (Cubic Feet/Minute)
1600 up to 0.7 in. W.C.
1200 up to 1.2 in. W.C.
Nominal Output Btu/hr at 140°F
1
50,000
Nominal Cooling Capacity
Up to 4 tons
Rated Voltage
120 V, 60 Hz, 1 Ph
Motor:
-
9.6A FLA, Pump 3A max
15A MOA, 20A MOP
Blower Motor Type
ECM fully variable
Coil Material
Copper Coil, Aluminum Fins
Blower Motor Horsepower (HP)
3/4
Water Connection
1/2 in. Sweat
Control Board
•
Factory Installed
•
Thermostat connections
•
Adjustable time delay for blower activation for heating
•
Pump timer circulates water for one minute every 24 hours
to prevent stagnation of water in the system (default)
P9
-
11 Energy Efficiency Rating (TPF)
0.88 with RU160i tankless water heater*
Certifications
CSA 22.2 No 236, UL
-
1995, NSF 372 (hydronic coil)
Rinnai products are continually being updated and improved; therefore, specifications are subject to
change without prior notice.
1 Reference tables in sections 3.7.2 for specific BTU output.
* Refer to P9
-
11 listings for latest information and results.