ICE Fixed Speed OIM
2. COMPONENTS
2.1 INDOOR UNIT (COOLING COIL)
Remove packaging from unit and any protective foam packing from coils and pipes. Indoor units are shipped
with a holding charge of dry nitrogen. Check to confirm the holding charge. For lifting details refer to the General
Arrangement drawings.
•
Brivis ICE indoor coil units shall be installed only downstream of a heater.
•
Brivis ICE is not designed for installation on a marine craft, houseboat, or any similar environment.
Figure 1. Indoor Cooling Coil
2.2 STARTING COLLARS
Insert starting collar (pop) into the hole in pop plate, ensuring pop flange is placed over the inner supply air wall of
the cabinet. Spread the pop flange to fit tight in the cabinet’s hole with the notch side of the collar over lapping the
other. Secure the pops with the rivets supplied.
Figure 2. Indoor Coil Starting Collar Assembly
Rivets
(Supplied)
Pop
Illustrated DI-XU22Z