INSTALLATION INFORMATION
Rinnai 10
Split Collector IM
WARNING
When connecting collectors or copper pipe with compression unions, ensure that the compression
union is held at 2 points as shown in the diagram. One side should be held still while the other is
tightened. Not doing this can cause damage to the collector or leaks.
WARNING
When connecting the collectors with compression unions, ensure that the collectors are pushed
together so that the olive is sitting approximately 15mm from the end of the copper pipe. This ensures
the join will survive the expansion and contraction that can occur due to temperature fluctuations.
15 mm
Collector header pipework to be
pushed up hard against the nipple
This ensures the copper olive is
adequately pushed onto the the pipe.
Collector header pipes
Olive
Nipple