98
Rinnai Direct Vent Service Manual
RHFE-1004FA
Gas Pressure Setting Procedure
7. Press the ON/OFF button to operate the
appliance.
8. Press the SW1 switch. The LED will display
“78” or “7 ”.
9. Press the SW1 switch again to change to the
low pressure mode. The LED will display
“PL”.
10. Compare the pressure reading on the
manometer to the correct table for your gas
type. If necessary adjust the low fire pressure
using the
▲
and
▼
buttons.
11. Press the Economy button. The LED will
display “18” indicating that the low pressure
has been recorded into memory.
12. Press the SW1 switch
TWICE
. This puts the
appliance into the high fire mode. The LED
will display “PH”.
13. Compare the pressure reading on the
manometer to the correct table for your gas
type. If necessary adjust the high fire
pressure using the
▲
and
▼
buttons.
14. Press the Economy button to enter the high
fire pressure into memory. The LED display
will display “78”. If the LED shows any thing
other than “78” call Rinnai Technical Support
at 1-800-621-9419 for assistance.
15. Press the ON/OFF button again. The LED
display turns blank and the appliance returns
to the normal OFF mode.
17. Remove manometer and install Allen head
screws. Operate the unit and
CAUTION
Do not insert hands or objects into the circulation
fans while they are running. Injury or mechanical
malfunction may occur.
CAUTION
Do not touch the areas at or near the heat
exchanger or burner. These areas become very
hot and could cause burns.
Check that the burner flames are operating normally.
The flame can be seen through the circular window
through the louvers.
When operating normally the burner flame should
appear as long, clear, blue, stable, streaks. Yellow
flames or an orange color is abnormal and
maintenance is required.
Visual Inspection of Flame
Install the front panel and bottom cover.
Final Assembly
Normal Operating Sequence
When you press the ON/OFF button, the LED display
will illuminate, the combustion fan will begin to run,
and the spark will ignite the main burner.
This heater has an automatic ignition system. When
the main burner has lit, the combustion lamp will glow
red, and the spark will stop.
•
check the normal operating sequence
•
visually inspect the flame
•
check for gas leaks at the test points
Summary of Contents for Energysaver RHFE-1004FTA
Page 14: ...14 Rinnai Direct Vent Service Manual RHFE 201FA RHFE 201RFA Wire Diagram ...
Page 15: ...Rinnai Direct Vent Service Manual 15 RHFE 201FA RHFE 201RFA Ladder Diagram ...
Page 18: ...18 Rinnai Direct Vent Service Manual RHFE 263FA RHFE 263FAII RHFE 263RFA Wire Diagram ...
Page 19: ...Rinnai Direct Vent Service Manual 19 Ladder Diagram RHFE 263FA RHFE 263FAII RHFE 263RFA ...
Page 26: ...26 Rinnai Direct Vent Service Manual RHFE 431FA Series RHFE 556FA FTRA Wire Diagram ...
Page 27: ...Rinnai Direct Vent Service Manual 27 RHFE 556FAIII Wire Diagram ...
Page 28: ...28 Rinnai Direct Vent Service Manual RHFE 556FTRAIII Wire Diagram ...
Page 32: ...32 Rinnai Direct Vent Service Manual RHFE 431WTA Wire Diagram ...
Page 33: ...Rinnai Direct Vent Service Manual 33 RHFE 556WTA Wire Diagram ...
Page 45: ...Rinnai Direct Vent Service Manual 45 RHFE 551FA Fault Finding Summary ...
Page 46: ...46 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 1 ...
Page 47: ...Rinnai Direct Vent Service Manual 47 RHFE 551FA Fault Finding Chart 2 ...
Page 48: ...48 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 3 ...
Page 49: ...Rinnai Direct Vent Service Manual 49 RHFE 551FA Fault Finding Chart 4 ...
Page 50: ...50 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 5 ...
Page 51: ...Rinnai Direct Vent Service Manual 51 RHFE 551FA Fault Finding Chart 6 ...
Page 52: ...52 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 7 ...
Page 53: ...Rinnai Direct Vent Service Manual 53 RHFE 551FA Fault Finding Chart 8 ...
Page 54: ...54 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 9 and 10 ...
Page 55: ...Rinnai Direct Vent Service Manual 55 RHFE 551FA Wire Diagram ...
Page 58: ...58 Rinnai Direct Vent Service Manual RHFE 1001FA Fault Finding Chart ...
Page 59: ...Rinnai Direct Vent Service Manual 59 RHFE 1001FA Fault Finding Chart ...
Page 60: ...60 Rinnai Direct Vent Service Manual RHFE 1001FA Fault Finding Chart ...
Page 61: ...Rinnai Direct Vent Service Manual 61 RHFE 1001FA Wire Diagram ...
Page 64: ...64 Rinnai Direct Vent Service Manual RHFE1001FA VA Fault Finding Chart ...
Page 65: ...Rinnai Direct Vent Service Manual 65 RHFE1001FA VA Fault Finding Chart ...
Page 66: ...66 Rinnai Direct Vent Service Manual RHFE1001FA VA Fault Finding Chart ...
Page 67: ...Rinnai Direct Vent Service Manual 67 RHFE1001FA VA Fault Finding Chart ...
Page 68: ...68 Rinnai Direct Vent Service Manual RHFE 1001FA VA Wire Diagram Wire Diagram Ladder Diagram ...