FEATURES
EX22 (RHFE-558RWTA)
Type of Appliance
Rinnai Model Number
Gas Rate Input (BTU/hour)
Gas Rate Output (BTU/hour)
AFUE Rating
Minimum Gas Supply Pressure
Maximum Gas Supply Pressure
Electrical Connection
Gas Connection
Combustion System
Ignition System
Fan CFM Output:
Temperature Settings
Temperature Control
Humidifier Tray
Weight
Clearance from Combustibles
Noise Level
Warm Air Outlet
Direct vent wall furnace suitable for homes, apartments, and )
condominiums; modular/mobile home approved; forced combustion,
forced convection
RHFE-558RWTA-N (Natural gas) RHFE-558RWTA-P
(Propane)
Low - 8,200
Low - 8,200
High - 21,500
High - 20,700
Low - 6,560
Low - 6,560
High - 17,200
High - 16,560
80.6% 81.0%
3.5 in (89 mm) W.C.
8 in (203 mm) W.C.
10.5 in (267 mm) W.C
13 in (330 mm) W.C.
AC 120V, 60 Hz, 47 watts
1/2 inch FNPT
Stainless steel inshot burners
Direct spark
Low: 110.5
High: 162.7
Low (LO): minimum combustion
60° - 80° F in 2° increments
High (HI): maximum combustion
•
Electronic 7 day, 28 event programmable set back thermostat
•
Frost protection function allows a pre-set minimum room temperature
•
Temperature limiting program to comply with Inside Design
Temperature limits
Enameled tray with capacity of 3 pints (1.3 liters)
Approximately 51 lbs (23 kg)
Side: 2 inches (50 mm)
Top: 10 inches (250 mm)
Front: 40 inches (1 m)
32 - 41 dB(A)
Bottom front louvers
© 2009 Rinnai Corporation
RHFE-558RWTA SP 7/2009
provides precise gas flow
detects temperature change in 1/2 of a degree
monitors and controls combustion fan
reduces noise through use of swept blades in convection fan; and
through the design of the combustion chamber and heat exchanger
which silently expand or contract due to temperature changes
continually monitors functions; provides auto shutdown codes; indicates
when air filter needs cleaning
Linear function modulation:
Negative coefficient thermistor:
Variable speed inducer motor:
Quiet operation:
Self diagnostic electronics: