18
EX38DT Installation and Operation Manual
3. Install the Sleeve.
Attach the sleeve to the inside wall using 3 screws arranging the flange so that the marking
“TOP” is at the top. The flange is offset 2° to allow the condensate drain to the outside.
Apply silicone sealing evenly around the perimeter of the outside sleeve to avoid water intrusion.
4. Install the Terminal.
Check that the terminal seal is in place. For weatherboard walls, add the second seal next to the
terminal seal to compensate for weather board angle. Adjust the second seal to make sure “Top”
marking of the second seal is located at the top or “
Ʌ
” marking is aligned with “V” marking on the
terminal.
From the outside insert the terminal into the sleeve with the marking “TOP” at the top. The left
hand side locking tie should be marked “LEFT”.
3 screws
Sleeve should extend
3/16 - 3/8 in (5-10 mm)
Figure 14
Indoor
Outdoor
Apply silicone
sealing evenly
around the
perimeter.
Top Terminal
seal
Apply silicone
sealing evenly
around the entire
seal.
Put silicone sealing evenly around the perimeter without any
gaps between the terminal seal and rough wall surface.
Figure 15
Locking tie
(
Ʌ
)
(V)
Terminal
Summary of Contents for EX38DT
Page 41: ...EX38DT Installation and Operation Manual 41 8 Parts Cut Away Diagram Figure 58 ...
Page 42: ...42 EX38DT Installation and Operation Manual Exploded View of Service Parts Figure 59 ...
Page 43: ...EX38DT Installation and Operation Manual 43 Exploded View of Service Parts Figure 60 ...
Page 44: ...44 EX38DT Installation and Operation Manual Exploded View of Service Parts Figure 61 ...
Page 45: ...EX38DT Installation and Operation Manual 45 Exploded View of Service Parts Figure 62 ...
Page 46: ...46 EX38DT Installation and Operation Manual Exploded View of Service Parts Figure 63 ...