24
EX38DT Installation and Operation Manual
4.4.6 Connect the Direct Vent Furnace
1. Attach flue adapter to the flue manifold with
pipe stopper S.
2. Attach the air inlet hose to the flue
manifold. Secure with plastic tie. The
unused inlet is plugged with the rubber cap
supplied on the manifold.
3. Connect the vent sliding tube with pipe
stopper S and A.
4. Slide the insulation sleeve up to the flue
manifold and slip the securing clip over the
sleeve as shown.
5. Attach the furnace to the wall brackets,
using 2 screws at each bracket.
6. Attach the back spacer with 3 screws to the
top of the furnace.
7. If necessary, the furnace can be leveled
using the adjustable legs under the front
right and left legs.
Up to
3/8 in.
(10 mm)
Adjustable Leg
Pipe Stopper S
Flue Adapter
Flue Manifold
Plastic Tie
Inlet Hose
Inlet
Elbow
Flue Manifold
Sliding Tube
Pipe Stopper A
Pipe Stopper S
Figure 28
Figure 27
Figure 29
Figure 31
Figure 30
Screw
(M5)
Figure 32
Insulation
Sleeve
Summary of Contents for EX38DT
Page 41: ...EX38DT Installation and Operation Manual 41 8 Parts Cut Away Diagram Figure 58 ...
Page 42: ...42 EX38DT Installation and Operation Manual Exploded View of Service Parts Figure 59 ...
Page 43: ...EX38DT Installation and Operation Manual 43 Exploded View of Service Parts Figure 60 ...
Page 44: ...44 EX38DT Installation and Operation Manual Exploded View of Service Parts Figure 61 ...
Page 45: ...EX38DT Installation and Operation Manual 45 Exploded View of Service Parts Figure 62 ...
Page 46: ...46 EX38DT Installation and Operation Manual Exploded View of Service Parts Figure 63 ...