28
|
Neo RIB2312 installation guide: 12148-A 01-17
Flame pattern
It may take approximately two hours of operation for the logs to achieve their
full flame pattern and glow. During the initial burning in period, some smoke and
smell may be experienced. The appliance should run on the high setting in a well
ventilated room until these dissipate. It is important to check the flame pattern
during this time.
Abnormal flame pattern
Abnormal flame performance and/or pattern can indicate a problem with the fire, such as
blocked gas injectors, or that the log set (burn media) has shifted. There are some warning signs
that could indicate a problem.
- Unusual smell from the appliance
- Continued difficulty or delay in establishing a flame
- Flame appears either very short or very long
- Flame only burns part way across the burner
- Severe soot building up on the inside of the glass
Important
It is the responsibility of the installer to check that under normal conditions of the appliance, all
flue gases are exhausted to the outside atmosphere, and that there is no spillage of combustion
gases into the room.
If the appliance cannot be made to perform correctly please contact Rinnai.
Normal flame pattern
Abnormal flame pattern
Soot build up
Customer handover
Complete the installation and commissioning checklist in the customer operation
guide, and make sure you leave the guide with the customer. Explain to the
customer about the use and care of the unit, and that they understand the
instructions and operation of the appliance.