background image

 

Pipe Cover Enclosure Installation Instructions      

 

 

Copyright © 2018 Rinnai America Corporation. All Rights Reserved.

 

 

 

 

 

2

 

Rinnai Corporation continually updates materials, and as such, content is subject to change without notice. Local, state, provin-

cial, federal and national fuel gas codes must be adhered to prior to and upon installation.

 

   B

 

   C

 

A

 

A

 

2.

 

Remove the four mounting screws and plastic washers       from the outside 
bottom of the water heater and retain for use in the next step.

 

3.

 

Install the two L brackets ⑤ to the bottom of the water heater with the 
screws and washers        removed in step 2, ensuring the tab of the L brackets 
face to the outside of the water heater.

 

Water  Heater Preparation

 

Pipe Cover Installation

 

4.

 

Temporarily fit the pipe cover enclosure to the L brackets ⑤, using two 
screws ⑦ (one per side). DO NOT fully tighten the screws as they will be 
removed again in a later step.

 

5.

 

Loosen the screws of the back bottom frame ① and move the frame into 
its final position. Then, re

-

tighten the screws.

 

6.

 

Select two suitable fixing points through the back of the bottom frame ① 
and mark off their position on the wall.

 

7.

 

Remove the pipe cover enclosure from the water heater and drill two 
holes in the wall as marked. If using the wall anchors ⑨ supplied, a 5 mm 
(0.2 in.) diameter hole to the depth of 25 mm (1.0 in.) is required.

 

8.

 

Gently tap the wall anchors ⑨ into the drilled holes until flush with the 
wall surface.

 

9.

 

Press plastic retaining clips ⑥ through the panel and into the 

 

L bracket. 

 

10.

 

Refit and secure the pipe cover enclosure to the L brackets ⑤ using the 
screws ⑦ and plastic washers ⑧.

 

11.

 

Secure the pipe cover to the wall through the back bottom frame ① with 
two screws ⑩.

 

13.

 

DO NOT perform the following instructions on Australian 
installations:  

To secure the front panel ④ to the pipe cover 

enclosure, open the four tabs at the top and bottom corners 
and secure with screws ⑦and plastic washers ⑧ . Next, close the tabs. 

 

12.

 

Attach the front panel ④ to the pipe cover enclosure by inserting 
the four tab hooks on the front panel          into the slots        of the 
left panel ② and right panel ③ (see tab hook and slot detail 
below). 

 

Front Panel Installation

 

Insert Tab Into Slot

 

Tab Fully Inserted 

Into Slot

 

U290

-

1022X03(00) 100000403(01)

 

070 00012 51891 6

 

NOTE: 

Some models do not include plastic covers, for these applications secure front panel to the pipe cover 

enclosure with screws ⑦and plastic washers ⑧ . 

 