Installation & Servicing Instructions Rinnai Q Premier
9
Room sealed boiler
The boiler retreives its
combustion air from outside
then discharges the
fl
ue
gasses to the outside.
Condensing
Retrieves heat as much as
possible from the
fl
ue gasses.
Water condensates on the
heat exchanger.
Modulating
Stepless higher or lower
burning according to the heat
demand.
3
Description of the boiler
The Rinnai Q Premier boiler is a room sealed, condensing and modulating central
heating boiler, with an integrated DHW cylinder.
The boiler is provided with a compact stainless steel heat exchanger with smooth
tubes. This design is a well engineered principle using durable materials.
The boiler burns gas for supplying heat. The heat is transferred in the heat exchanger
to the water in the central heating system. By cooling down the exhaust gases
condensate is formed. This results in high ef
fi
ciency. The condensate, which has
no effect on the heat exchanger and the function of the boiler, is drained through a
condensate collector trap.
The boiler is provided with an intelligent control system (CMS Control Management
System). The boiler anticipates the heat demand of the central heating system or the
domestic hot water facility system.
When an outdoor sensor is connected to the boiler it will operate weather dependantly
using outdoor reset. This means that the boiler control measures the outside
temperature and supply temperature. With this data the boiler calculates the optimal
supply temperature for the installation.
Explanation of the type indication: Rinnai QP130N
QP
=
Type
130 = Nominal load in (x1,000) BTU
N = Natural Gas
4
Packaging and transportation
4.1 Scope of delivery
The boiler is supplied ready for use.
•
Please check if the packaging is intact.
•
Check if all the items listed are included in the delivery.
The supply kit contents:
Part No.
Description
Amount
QP85N
QP130N
Boiler with:
ARV1215U Outdoor reset sensor ARV12
1
44323420
Cover air supply Ø120/Ø80
1
44323510
Gasket vent system ø80
1
44440520
Flue pipe Ø 80 PP
1
44472600
Lip-ring flue pipe ø80
1
44770110
Flue adapter Ø80/Ø3" pps UL appr.
2
44021000
Gasket set hydraulics (5x EPDM)
5
44637900
Gasket set gas (6x Fiber)
1
8U51540x Installation & Service Instructions
1
8U52540x User information manual
1
8U304000 Warranty document
1
8U300600 ICSL book
1