15
ERROR MESSAGES
Troubleshooting without controllers
If you have not installed temperature controllers and experience the following
symptoms, please carry out the suggestions below. If symptoms continue, please
contact Rinnai for advice.
NOTE: Faults caused by insufficient gas/water supply or gas/water quality and
installation errors are not covered by the manufacturer’s warranty.
Installations with circulation pumps
With temperature controller fitted.
If you have an installation using a secondary circulation pump this must be switched off
so that there is no flow through the heater when starting or after a power failure. If the
pump is running the unit will not operate (no display on the controller). Isolate pump
then start heater before restarting pump. This is a safety feature.
The pump should also be fitted with a timer to prevent the consumption of energy while
the building is not used. The timer should bring the system back on at least one hour
before it is to be used.
Without temperature controller fitted.
The heater should automatically reset and provide water at the temperature set by the
internal limit switches.
Fault
Remedy
Heater does not attempt
to start at all.
Check the power is on at the heater.
Check the cold water valve supplying the heater is open.
Heater starts then shuts
down immediately.
Check the power is on.
Check the gas valve at the heater and at the gas meter is fully open.
Open the hot water tap fully.
Heater starts then the
water goes cold.
Check the power is on.
Open your hot water tap further or try another hot outlet.
Summary of Contents for R E U - K M2635FFUDHD-E
Page 20: ...20 OPERATION Infinity K32e and HDC1500e Infinity K32i and HDC1500i...
Page 21: ...21 OPERATION Infinity K26e and HDC1200e Infinity K20i K26i HDC1000i and HDC1200i...
Page 33: ...33 CONDENSATE DISPOSAL...
Page 42: ...42 DIMENSIONS Infinity K32i and HDC1500i Infinity K32e and HDC1500e...
Page 43: ...43 DIMENSIONS Infinity K20i K26i HDC1000i and HDC1200i Infinity K26e and HDC1200e...
Page 49: ...49 FLOW CHART...
Page 50: ...50 WIRING DIAGRAM Infinity K32 5 amp...
Page 51: ...51 WIRING DIAGRAM Infinity K20 K26 5AMP FUSE...
Page 52: ...52 DIAGNOSTIC POINTS Infinity K20 K26 Infinity K32 Y Y...
Page 53: ...53 WATER FLOW CHARACTERISTICS Infinity K32 Infinity K20 K26...
Page 54: ...54 LETTER OF COMPLIANCE...
Page 55: ...55 CE CERTIFICATE...
Page 56: ...56 CE CERTIFICATE...
Page 58: ...58 COMMISSIONING SHEET...
Page 59: ...59 SERVICE RECORD...