38
GAS PRESSURE SETTING
The working gas pressure on the water heater is electronically controlled and factory set.
Under normal circumstances it
does not
require adjustment during installation. The
pressure should be checked when the unit is installed and each time it is serviced to ensure
that it is correct.
Contact Rinnai before attempting to alter the gas pressure if you are
unsure of what to do. Incorrect adjustment can void the warranty.
1. Turn 'OFF' the gas supply.
2
. Turn 'OFF' 23
0
V power supply.
3
. Remove the front cover from the appliance.
4. Check gas type dip switch no.1 of SW2 is in the correct position for the type of gas (Nat.
or LPG)* you are using. See Fig. 1
5
. Attach pressure gauge to burner test point. (Fig. 2)
6
. Turn 'ON' the gas supply.
7
. Turn 'ON' 23
0
V power supply.
8
. If remote controllers are fitted, turn the unit 'ON' at the controller and select a maximum
delivery temperature.
9. Open a hot water tap fully.
(CAUTION: Ensure building occupants do not have
access to hot water outlets during this procedure.)
Wait for the unit to light.
* Simply changing the position of the dip switches will not convert the
unit from one gas type to the other. The conversion procedure requires
a change of injector manifold. Contact Rinnai or your supplier.
NOTE
K20 & HDC1000
K32 & HDC1500
K26 & HDC1200
Summary of Contents for R E U - K M2635FFUDHD-E
Page 20: ...20 OPERATION Infinity K32e and HDC1500e Infinity K32i and HDC1500i...
Page 21: ...21 OPERATION Infinity K26e and HDC1200e Infinity K20i K26i HDC1000i and HDC1200i...
Page 33: ...33 CONDENSATE DISPOSAL...
Page 42: ...42 DIMENSIONS Infinity K32i and HDC1500i Infinity K32e and HDC1500e...
Page 43: ...43 DIMENSIONS Infinity K20i K26i HDC1000i and HDC1200i Infinity K26e and HDC1200e...
Page 49: ...49 FLOW CHART...
Page 50: ...50 WIRING DIAGRAM Infinity K32 5 amp...
Page 51: ...51 WIRING DIAGRAM Infinity K20 K26 5AMP FUSE...
Page 52: ...52 DIAGNOSTIC POINTS Infinity K20 K26 Infinity K32 Y Y...
Page 53: ...53 WATER FLOW CHARACTERISTICS Infinity K32 Infinity K20 K26...
Page 54: ...54 LETTER OF COMPLIANCE...
Page 55: ...55 CE CERTIFICATE...
Page 56: ...56 CE CERTIFICATE...
Page 58: ...58 COMMISSIONING SHEET...
Page 59: ...59 SERVICE RECORD...