Bypass Flow Servo
•
Measure the resistance values and
voltage of the bypass servo valve.*
•
Ensure the harness and connector are
not wet.
•
If the voltage from the PC Board is
abnormal, replace the PC Board;
otherwise, replace the bypass servo
valve.
70
PC Board
•
Check the connection harness at the
connection on the PC board.
•
Replace PC board.
71
Solenoid Valve Circuit
•
Ensure dip switch on PC board is in the
OFF position.
•
Check gas solenoid valves for short
circuits or grounding.
•
Ensure heater circuit is not grounded.
•
Replace PC Board.
72
Flame Sensing Device
•
Verify flame rod is touching flame when
unit fires.
•
Check the flame rod and wire for
damage.
•
Remove flame rod;check for carbon
build-up; clean with sand paper.
•
Check inside burner chamber for any
foreign material blocking flame at flame
rod.
•
Check the resistance to the cabinet.
•
If there is no issue with the flame rod or
wiring, replace the PC Board
79
Water Leak Detected
•
Turn off water supply and contact
licensed professional.
34
Combustion Air Temperature Thermistor
Fault
•
Check for restrictions in air flow around
unit and vent terminal.
•
Check sensor wiring for damage.
•
Measure resistance of sensor.
•
Ensure fan blade is tight on motor shaft
and is in good condition.
•
Replace sensor if necessary.
41
Freeze Protection Thermistor
•
Check sensor wiring for damage.
•
Measure resistance of sensor. (See
Electrical Diagnostics)
•
Replace sensor if necessary.
51
Inlet Water Temperature Thermistor
•
Check sensor wiring for damage.
•
Measure resistance of sensor. (See
Electrical Diagnostics)
•
Replace sensor if necessary.
52
Modulating Solenoid Valve Signal
•
Check modulating gas solenoid valve
wiring harness for loose or damaged
terminals.
•
Measure resistance of valve coil.
61
Combustion Fan
•
Ensure fan will turn freely.
•
Check wiring harness to motor for
damaged and/or loose connections.
•
Measure resistance of motor winding.
63
Recirculation Low Flow
•
Ensure the inlet water filter is clean and
free of debris.
•
Ensure parameter setting are correctly
set for recirculation mode.
•
Ensure pump supply voltage.
•
Check the wiring harness to the pump
and PCB for damaged and/or loose
connections.
•
Ensure air is removed from the
recirculation line.
65
Water Flow Servo
•
Measure the resistance values and
voltage of the water flow control.*
•
Ensure the harness and connector are
not wet.
•
If the voltage from the PC Board is
abnormal, replace the PC Board;
otherwise, replace the water flow servo
valve.
* See “Electrical Diagnostics” on Technical Data