19
1.4.7 RESERVATION mODE (RESERVATION)
The functioning of the ‘reservation mode’ will also be mentioned as
RESERVATION
.
The Rinnai Wifi’s chronothermostat consents you to set time slots for the heating mode every day. It is possible to
program the favourite time slots during which the boiler must maintain a comfortable temperature and those during
which it is allowed to reduce the temperature (night time or whenever nobody is at home).
The specific time reservation works both in ‘room temperature’ mode and in ‘flow temperature’ mode and works
exclusively on the heating mode but not on the domestic hot water production.
To activate and program the RESERVATION mode, perform the following steps.
:
•
set the intended time on the chronothermostat (see
par. 1.4.1
)
•
Press button
(
1
);
•
Press button
TIMER
once(
2
):
the icon
.
flashes on the display, meaning that the specific time
program nr.1 of the RESERVATION mode has been activated;
•
Press button
TIMER
several times to select the intended time slot:
The programs from number one to three are predefined and cannot
be modified, while the specific time programs number four and five can be personalized;
•
to confirm the selection of the intended time in the program is sufficient to wait a few seconds: the icon of the
intended specifics time slots will stop blinking.
•
The specific time reservation will be completed by defining the temperatures
T1
(daytime) and
T2
(reduced) in
the
menu A
(
parameters 6
and
7
) of the chronothermostat functions (see
par. 1.4.8
):
the temperature T1 is used by the boiler during the intended and selcted specific times (highlighted in orange
in the time slot); but the temperature T2 is used during the unselected time slots.
To exit RESERVATION mode during the operation
:
•
Press the button
TIMER
: the boiler will go back to normal operation.
By re-activating RESERVATION mode, the system will re-open the previously selected program.
personalizing the reservation mode
Only the programs four and five can be personalized. The use of ‘My Rinnai’ application allows to select a more
detailed time slots programming schedule.
To select the time slots, perform the following steps
:
•
Press button
TIMER
until it is possible to select a program
.
o
.
;
•
Turn the dial (
1
) and drag the orange flashing selector of the hour bar on the intended time;
•
Press the dial (
2
) to confirm the selection of the intended time;
•
Repeat the previous operations util you have completed the intended pattern;
•
The reservation is completed when temperature
T1
(daytime) e
T2
(reduced) are defined in the
menu A
(
parametres 6
and
7
) of the thermostat functions (see
par. 1.4.8
):
the boiler uses temperature T1 in correspondence to the selected time slots (highlighted in orange in the time
schedule); the temperature T2 is used during the unselected time slots.
MENU
AUTO
ON
OFF
TIMER
ENERGY
MONITOR
SAVE
2
PUSH
1
►
►
►
►
►OFF
PUSH
2
PUSH
1